beautypg.com

B= (set baud rate) – PNI TCM 2.6 User Manual

Page 32

background image

PNI Sensor Corporation

DOC#1009269 r11

TCM2.5 & TCM2.6 User Manual

Page 32 of 49

User Configuration Parameter Commands


The following commands allow you to set and query the values of the TCM2.5/2.6’s user configura-
tion parameters. These parameters specify how the TCM2.5/2.6 will operate, such as damping,
baud rate, and so on. The TCM2.5/2.6 stores all parameter values in EEPROM when specified, so
that after a reboot or power cycling, it will return to the last configuration set. Note that any parame-
ter that specifies a numeric value must be specified with the appropriate units of the current setting.

b=

(Set Baud Rate)

Description

Sets the baud rate for the RS232 interface. Note: This is now an immediate

command and a reset is no longer required.

Syntax

b=n

Output

:

Valid Values

Input

Baud Rate

1

300

2

1200

3

2400

4

4800

5

9600 (default setting)

6

19200

7

38400

8

115200

Table 9: Valid

b= Values

Example

b=5

!set baud rate to 9600 baud

:

Query Response

b?

:b=

This manual is related to the following products: