B= (set baud rate) – PNI TCM 2.6 User Manual
Page 32
PNI Sensor Corporation
DOC#1009269 r11
TCM2.5 & TCM2.6 User Manual
Page 32 of 49
User Configuration Parameter Commands
The following commands allow you to set and query the values of the TCM2.5/2.6’s user configura-
tion parameters. These parameters specify how the TCM2.5/2.6 will operate, such as damping,
baud rate, and so on. The TCM2.5/2.6 stores all parameter values in EEPROM when specified, so
that after a reboot or power cycling, it will return to the last configuration set. Note that any parame-
ter that specifies a numeric value must be specified with the appropriate units of the current setting.
b=
(Set Baud Rate)
Description
Sets the baud rate for the RS232 interface. Note: This is now an immediate
command and a reset is no longer required.
Syntax
b=n
Output
:
Valid Values
Input
Baud Rate
1
300
2
1200
3
2400
4
4800
5
9600 (default setting)
6
19200
7
38400
8
115200
Table 9: Valid
b= Values
Example
b=5
!set baud rate to 9600 baud
:
Query Response
b?
:b=