Sn= (select magnetic or true north) – PNI TCM 2.6 User Manual
Page 39
![background image](/manuals/373149/39/background.png)
PNI Sensor Corporation
DOC#1009269 r11
TCM2.5 & TCM2.6 User Manual
Page 39 of 49
sn=
(Select Magnetic or True North)
Description Selects either magnetic or true north. True North sets the heading reference to True
North or Magnetic North. If the value is set to true, then declination is applied to get
the True North heading.
Syntax
sn=n
Output
:[Ennn]
Valid Values
Input
Description
t
True North
m
Magnetic North (default setting)
Table 19: Valid
sn= Values
Example
sn=t
!the declination angle set with mag_dec is added to the
!computed heading
:
Query Response
sn?
:sn=
Related Commands
mag_dec= (Set Declination Angle)