Heat Pump Cooling Fixed Capacities
Summer Ambient (°C)
25
30
35
40
45
Unit
Evap
Temp
(°C)
Output
(kW)
Input
(kW)
Output
(kW)
Input
(kW)
Output
(kW)
Input
(kW)
Output
(kW)
Input
(kW)
Output
(kW)
Input
(kW)
CUR092V16-1HP-0
-5
10.3
3.9
10.3
3.8
9.8
4.2
9.2
4.6
8.5
5.0
0
12.4
3.9
12.2
3.9
11.6
4.3
11.0
4.7
10.3
5.2
5
14.8
3.9
14.4
4.0
13.7
4.4
13.0
4.8
12.2
5.3
7
15.9
3.8
15.4
4.0
14.6
4.4
13.8
4.8
13.0
5.3
10
17.6
3.7
16.9
4.0
16.0
4.4
15.2
4.9
14.3
5.3
CUR092V20-1HP-0
-5
15.8
5.5
15.1
5.8
14.3
6.3
13.3
6.8
N/A
N/A
0
18.7
5.5
17.9
6.0
17.0
6.5
15.9
7.0
14.8
7.6
5
21.9
5.7
20.9
6.1
19.8
6.6
18.7
7.2
17.5
7.7
7
23.3
5.7
22.2
6.2
21.1
6.7
19.9
7.2
18.7
7.8
10
25.4
5.8
24.2
6.3
23.0
6.8
21.8
7.3
21.1
6.7
CUR092V25-1HP-0
-5
20.3
7.0
19.3
7.7
18.3
8.4
17.1
9.1
N/A
N/A
0
24.0
7.4
22.8
8.0
21.5
8.7
20.1
9.5
N/A
N/A
5
28.1
7.8
26.6
8.4
25.0
9.1
23.3
9.9
N/A
N/A
7
29.8
8.0
28.2
8.6
26.5
9.3
24.6
10.1
N/A
N/A
10
32.4
8.2
30.6
8.9
28.8
9.6
26.7
10.3
N/A
N/A
CUR092V29-1HP-0
-5
22.5
8.0
21.2
8.7
19.9
9.5
28.7
10.6
N/A
N/A
0
26.5
8.4
25.0
9.1
23.4
10.0
21.6
10.9
N/A
N/A
5
30.8
8.9
29.0
9.6
27.1
10.4
25.1
11.4
N/A
N/A
7
32.6
9.0
30.7
9.8
28.7
10.6
26.6
11.6
N/A
N/A
10
35.4
9.3
33.3
10.1
31.1
11.0
28.7
10.6
N/A
N/A
CUR122V35-1HP-0
-5
30.5
11.8
29.0
12.9
27.2
13.9
25.3
15.1
N/A
N/A
0
36.1
12.3
34.2
13.2
32.1
14.3
29.8
15.5
N/A
N/A
5
42.1
12.7
39.9
13.7
37.4
14.8
34.8
15.9
31.9
17.3
7
44.6
12.9
42.3
13.9
39.7
14.9
36.9
16.1
33.9
17.5
10
48.6
13.2
46.0
14.2
43.2
15.3
40.2
16.4
39.7
14.9
CUR122V40-1HP-0
-5
34.5
13.5
32.7
14.5
30.7
15.6
28.6
16.8
N/A
N/A
0
40.4
14.1
38.3
15.1
36.0
16.2
33.5
17.4
N/A
N/A
5
46.9
14.8
44.4
15.7
41.7
16.8
38.8
18.1
N/A
N/A
7
49.6
15.0
47.0
16.0
44.1
17.1
41.0
18.4
N/A
N/A
10
53.9
15.4
51.0
16.5
47.8
17.6
44.5
18.8
N/A
N/A
Notes:
1
Output kW refers to the compressor duty.
2