BM 70M-EEx/ BM 70Mi-EEx

7

Device versions BM 70 M -EEx /V96

Temperature class

Ambient temperature [°C]

Maximum flange temperature [°C]

T6 60 85

55 100

T5

60 95

*)

40 125
45 120
50 110
55 105

T4 ... T1

60 95

*)

*) heat-resistant cable required (min. 80°C)

Device versions BM 70 M -EEx /SA

Temperature class

Ambient temperature [°C]

Maximum flange temperature [°C]

T6 60 85
T5 60 100

55 135

T4

60 135

*)

45 200
50 190

*)

55 170

*)

T3 ... T1

60 135

*)