115/230 V AC supply

Connection to a power source with dangerous contact voltage: if due to protective measures in
conformity with VDE 0100 a safety conductor PE is stipulated, it must be connected to the
separate U-clamp terminal in the terminal compartment of the signal converter.

Hazardous duty systems

The incoming cables for power supply are not of intrinsically safe design, not even in the
BM 70 M i version.

Electrical connection to be in conformity with VDE 0165, Section 5.6, or equivalent national
regulations.

Before making the electrical connection, make sure all cables leading into the BM 70 M-Ex are
disconnected from supply!

When used in hazardous locations, the BM 70 M-Ex must, in conformity with VDE 0165, be
incorporated in the PA equipotential bonding system, irrespective of the type of power supply.
If the PA is connected via a separate conductor, this must be connected to the outer U-clamp
terminal on the "neck" of the BM 70 M-Ex. Cancellation of equipotential bonding is only
permitted when the BM 70 M-Ex is disconnected from supply.