KROHNE BM 70 M User Manual
Page 36
36
BM 70 M
Function (Fct.)
Enter range
Default
value
Description
3.1.8 TB. OFFSET
Enter
-100.00 ... + 100.00 [m]
0.00 m
To input the tank
bottom offset
(relocation of the lower
reference point).
3.2 DISPLAY
Options LEVEL
DISTANCE
CONVERSION
3.2.1
FCT.DISP.
REFLECTION
LEVEL
Select function of the
display (value to be
displayed).
Options m
cm
mm
inch
Ft
PERCENT
3.2.2
UNIT.LENGTH
BARGRAPH
Meter [m]
Select unit for length
value to be displayed
(level/distance).
The unit selected here
is used only for display
of length values.
Options m3
l
US
Gal
GB
Gal
Ft3
bbl
PERCENT
BARGRAPH
3.2.3
UNIT.CONV
USER
UNIT
Cubic
meter
[m3]
Select unit for
conversion values to
be displayed ("volume
table").
The unit selected here
is used only for display
of the conversion
value
3.2.4 USER UNIT
Text entry
10 ASCII characters
________
Input of freely
programmable unit for
the conversion table
(max. 10 characters).
Options NO
3.2.5 ERROR MSG.
YES
YES
Select whether error
messages are to be
shown in the display
3.3 SIGNAL.OUTP.
Options OFF
LEVEL
DISTANCE
CONVERSION
REFLECTION
3.3.1 FUNCTION I
SW.OUTP.
LEVEL
Select function of the
current output
(measured value to be
displayed, or
OFF = current output
switched off = constant
4 mA).
Options 4-20
mA/E22
4-20
mA/E2
3.3.2 RANGE I
4-20
mA
4-20 mA/
E22
Select the range for
the current output and
error output.
3.3.3 SCALE 4 mA
Enter
-200.00 ... +200.00 [m]
0.00... 99999.99 [m3]
0 ... 100 [Refl.]
0.00 m
0.00 m3
0
Input the lower range
value for output to the
current output.
(Input is dependent on
the selected function
of the current output.
The values for level
and distance include
the tank bottom and
refe rence offset,
resp.).