71

PC-CAT allows convenient remote control of all functions of the signal converter. The vessel can
be shown in schematic form together with the associated measured values and the measured
spectrum. A trend graph of the output signal and threshold signal strength is also provided. All
relevant instrument data can be recorded in the form of a data set small enough to be stored on a
floppy disk or transferred electronically. Stored data can also be used for configuring other units
of the BM 70 product line.

PC-CAT files can later be used to analyse the performance of the level gauge. All graphs and
screens can be exported a word processing systems or other programs.

The customer’s PC containing PC-CAT is connected to the current output via the supplied PC
adapter, max. distance from the level gauge: 1000 m or 3300 ft. The PC adapter has no effect on
in-line instruments such as milliamperemeters, recorders, etc., connected to the current output.

9 Power

supply

9.1

Options, technical data

A choice is offered of 2 supply power versions:

Version

Voltage U

Tolerance

= voltage
range

Frequency Power

(typical) *

max. ripple /
harmonics

24V DC/
AC

24 V DC

-25% +30%

18-31.2 V

-

7.5 - 10 W

within limits
of tolerance

24 V AC

-25% +10%

18-26.4 V

45-66 Hz

10 VA

10%

115/230
V AC

115 V AC

-25% +10%

85-127 V

45-66 Hz

12 VA

10%

230 V AC

-25% +10%

170-254 V

45-66 Hz

12 VA

10%

* Hazardous-duty limit: 20W / 40 VA