beautypg.com

KROHNE BM 70 M User Manual

Page 80

background image

80

BM 70 M

Measured value:
± 0.08 mm/°C (quasi-static:

T < 0.5 °C/min)

± 5 mm (change

T > 0.5 °C/min)

Influence of the propagation way (in air or N

2

or O

2

):

-1 ppm/°C of measured distance

Effect of ambient temperature

Signal outputs: see above

Application conditions
Installation conditions

Avoid interfering reflections and multiple reflections

Ambient conditions

Zone 0,1,2
Temperature classes: T6...T1

Hazardous locations

Explosion groups: IIA...IIC

Ambient temperature of signal
converter

-40°C ... +60°C
(depends on flange temperature)
Horn antenna: -30°C … +200°C (depends on Tamb)

optional -60°C

Flange temperature

Solid antenna: -30°C … +125°C (depends on Tamb)

Ambient temperature limits

Signal converter
Measuring function OK, but LCD "freezes": min. -40°C

Functional upper limit, for max. 16 hours: max. +70°C

Storage temperature

-20°C ... +60°C

Climate class

Environmental category F acc. GL
Damp heat 55°C RH=95% for 96 hours
Salt mist (4 times) 5% NaCl spray periods 2 hours, storage 7
days at 40°C RH=93% acc. GL

Ingress protection

(Signal converter) IP 66 / IP 67 (equivalent to NEMA 6/6X)

Shock resistance

Impact test in conformity with EN 61010, Section 8.2 with 0.5
J energy and drop test to prEN 50178:1994

Vibration resistance

2-13.2 Hz: ±1 mm; 13.2-100 Hz: 0.7g
1 octave/min
3 axes: 90 min on each resonance (Q>2) or at 30Hz
3 axes acc. GL

Insulation

HV test min. 1500 V eff. acc. GL
Insul. resistance >10 M

at 500V DC

EMC

EN 50081-1, EN 50082-2
acc. Ship approvals: discharge 6kV/8kV
field 10V/m 80MHz-1GHz AM
burst 1kV/2kV
conducted 3Veff. 10kHz-80MHz AM
surge 1kV/2kV
cond. emiss. 10kHz-30MHz
rad. emiss. 150kHz-2GHz

Product conditions
Physical properties

No effect on measurement results
Minimum value or relative permittivity required to ensure
reliable measurements

Relative permittivity

r

>

r

< 2: stillwell recommended

Product limitations

Liquid ammonia(NH

3

) under pressure;

Liquid hydrogen(H

2

); liquid helium (He)

Product temperature

Unlimited (pay attention to ambient and flange temperature)

Operating pressure

Dependent on flange size and pressure rate;
standard: max. 16 bar