Technical data – KROHNE OPTIWAVE 6300C EN User Manual

Page 82

background image

8

TECHNICAL DATA

82

OPTIWAVE 6300 C

www.krohne.com

03/2014 - 4000547004 - HB OPTIWAVE 6300 R04 en

Measurement accuracy

Resolution

1 mm / 0.04¨

Repeatability

±1 mm / ±0.04¨

Accuracy

±3 mm / ±0.12¨, when distance < 10 m / 33 ft;

±0.03% of measured distance, when distance > 10 m / 33 ft

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Temperature

+20°C ±5°C / +70°F ±10°F

Pressure

1013 mbara ±20 mbar / 14.69 psia ±0.29 psi

Relative air humidity

60% ±15%

Target

Metal plate in an anechoic chamber

Operating conditions

Temperature

Temperature

Temperature

Temperature

Ambient temperature

-40…+80°C / -40…+175°F (according to the temperature limits of the gasket

material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Storage temperature

-40…+85°C / -40…+185°F

Flange temperature

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Standard: -50…+150°C / -58…+300°F

Option: -50…+200°C / -58…+390°F

(the process connection temperature must agree with the temperature limits of the

gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

-50…+150°C / -58…+300°F (the process connection temperature must agree with

the temperature limits of the gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

-40…+100°C / -40…+210°F (the process connection temperature must agree with

the temperature limits of the gasket material. Refer to "Materials" in this table.)

Ex: see supplementary operating instructions or approval certificates

Pressure

Pressure

Pressure

Pressure

Operating pressure

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

Drop antenna (PP):

-1…16 barg / -14.5…232 psig;

subject to process connection used and flange temperature

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

Drop antenna (PTFE):

-1…40 barg / -14.5…580 psig;

subject to process connection used and flange temperature

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Horn / Sheet metal horn antenna:

Standard: -1…40 barg / -14.5…580 psig;

subject to process connection used and flange temperature