6

OPERATION

56

OPTIWAVE 6300 C

www.krohne.com

03/2014 - 4000547004 - HB OPTIWAVE 6300 R04 en

Data dependencies for the 4 mA settings of outputs 1 and 2

C.5.1.4

Length Unit

The length unit displayed in operator

mode.

m, cm, mm, inch, ft, ft-inch-

1/16inch, ft-inch-1/32inch,

Free Unit

m

C.5.1.5

Volume Unit

The volume unit displayed in operator

mode.

m3, L, US gal, GB gal, ft3, bbl

m3

C.5.1.6

Mass Unit

The mass unit displayed in operator

mode.

Tons, Kg, US Tons, GB Tons

Kg

C.5.1.7

Custom.

Length Unit

A non-standard length unit for the

conversion table. This is defined by the

supervisor.

LEN_FREE_

C.5.1.8

Custom.

Length Ratio

The conversion factor between the

length unit selected in C.5.1.4 (Length

Unit) and C.5.1.7 (Custom. Length

Unit). This ratio is a multiple of 1 mm.

min.-max: 1…99999

1

C.5.1.9

Custom. Conv.

Unit

A non-standard conversion unit for the

conversion table. This is defined by the

supervisor.

CO_FR_UN

C.5.2

C.5.2

C.5.2

C.5.2

Passwords

Passwords

Passwords

Passwords

To change user passwords, refer to

To change user passwords, refer to

To change user passwords, refer to

To change user passwords, refer to

these menu items.

these menu items.

these menu items.

these menu items.

C5.2.2

Supervisor

This changes the supervisor password.

Push the keypad buttons up to 6 times

in any order. This will be the new

password. To confirm the change,

enter the new password a second time.

[>>>>], [^

^

^

^], [

],

[

], [>

>>>], [^

^

^

^]

C.6 Reset

C.6.2

Clear Error

Record

Erase the error record in menu item

B.2.6. Push [^

^

^

^] to confirm.

C.6.3

Restart

If the device is not functioning properly,

this menu item will restart the device.

Push [^

^

^

^] to confirm.

1 Units and range depend on the output function, length unit and volume unit selected. See also the table of data dependencies for the

4 mA settings in this section.

2 Units and range depend on the output function, length unit and volume unit selected. See also the table of data dependencies for the

20 mA settings in this section.

Output function

Minimum value

Maximum value

Default

Level

0 m

<20 mA Setting for Level

0 m

Volume

0.00 m³

<20 mA Setting for Volume

0 m³

Mass

0.00 kg

<20 mA Setting for Mass

0 kg

Distance

0 m

<20 mA Setting for Distance

0 m

Ullage Volume

0.00 m³

<20 mA Setting for Ullage Volume

0 m³

Ullage Mass

0.00 kg

<20 mA Setting for Ullage Mass

0 kg

Menu

No.

Function

Function description

Selection list

Default