beautypg.com

Operation – KROHNE OPTIWAVE 6300C EN User Manual

Page 48

background image

6

OPERATION

48

OPTIWAVE 6300 C

www.krohne.com

03/2014 - 4000547004 - HB OPTIWAVE 6300 R04 en

4

Distance

If the silo is partially filled, type

in a distance shorter than that

between the flange and the

tank contents.

min-max:

0…tank height

10 m /

32.808 ft

5

Do you want to

consider Average

or Maximum value

for recording?

Use the average value for silos

which contain fixed objects

only. Use the maximum value

for silos which contain many

objects or moving objects.

Average, Maximum

Average

6

Empty spect.

recording is in

progress

7

Empty spectrum

graph

8

Do you want to

save the

spectrum?

If you save this data, the device

will use it when it measures

the silo contents.

Save, Cancel

3

Save

A.1.4

A.1.4

A.1.4

A.1.4

Conversion

Conversion

Conversion

Conversion

Follow this procedure to set

Follow this procedure to set

Follow this procedure to set

Follow this procedure to set

the device up to display

the device up to display

the device up to display

the device up to display

readings in volume, mass or

readings in volume, mass or

readings in volume, mass or

readings in volume, mass or

user-defined units.

user-defined units.

user-defined units.

user-defined units.

Sub-

menu

Conversion

submenu [Volume]

[Volume]

[Volume]

[Volume]

1

Do you want to use

free unit?

Select "No".

Yes, No

No

2

Table Length Unit

m, cm, mm, inch, ft, Free

Unit

m

3

Please select

Volume / Mass

Select "Volume".

Volume

4

Tank Shape

This sub-procedure uses the

information given here to find

the volume. You have to type in

the silo shape, height, width

and length.

...

...

5

Conversion Unit

The displayed unit in operator

mode.

m3, L, US gal, GB gal, ft3,

bbl

m3

6

Volume Table

A table that converts product

level to product volume.

Push[

] or [

] to select a line

and push [>>>>] to change values

automatically supplied by the

device.

Sub-

menu

Conversion

submenu [Mass]

[Mass]

[Mass]

[Mass]

1

Do you want to use

free unit?

Select "No".

Yes, No

No

2

Table Length Unit

m, cm, mm, inch, ft, Free

Unit

m

3

Please select

Volume / Mass

Select "Mass".

Mass

4

Do you want to use

the density of the

product?

Yes, No

Yes

5

Product Density

min-max:

0…20000 kg/m3

0

Menu
No.

Step

Function

Function description

Selection list

Default