beautypg.com

Gsp-810 user manual – GW Instek GSP-810 User Manual User Manual

Page 28

background image

GSP-810 User Manual

26

POWER METER (Optional)

To access the power meter in the GSP-810, press the SHIFT PWR MTR. The

bottom half of the screen will show the power level in mW or dBm based on the

units selected in the setup screen. The range field will allow the user to change the

range of 2mW, 20mW, 200mW and 2W (or equivalently 3dBm, 13dBm, 23dBm and

33dBm). The AUTO option is helpful when the input signal power is unknown. If the

reading under AUTO selection is close to any one of the four level boundaries as

mentioned above, it is recommended to use the two next ranges to do again. In

general, the lower range will be more accurate.

The 4-digit frequency field specifies the frequency of the signal to measure. This

field is independent of the Center Frequency field as it is only used for the power

meter.

The “ZERO” function will zero the power meter in all ranges required. This should

be performed before taking initial readings. When performing a zero function, there

should be no signal source connected to the GSP-810.

The power meter readings will continuously update as long as the power meter is

active. A power reading of “-

∞” indicates a value of 0 mW in dBm units.

CENTER

SPAN

REF LVL

RBW

7

8

.

6

SHIFT

PK->MKR

MKR->CF

SETUP

TRACE

MKR

MKR

E
N
T
E
R

MHz

dBm

4

5

2

1

0

3

9

-

SPAN

CENTER

REF LVL

DEMOD

MEM

TRK GEN

RBW

PWR MTR

.

500.000MHz

20 dBm

100 MHz/div

4 MHz

RANGE: 2W 10MHz

POWER:-10dBm ►ZERO

500.000MHz

20 dBm

100 MHz/div 4 MHz
RANGE: 2W 10MHz
POWER:-10dBm►ZERO