Manual overview – GW Instek GDS-122 User Manual User Manual

Page 7

background image

Getting

Started

13

MENU key +

Up/Down keys

DSO

Activates the side menu and selects the 
menu items. 

RUN/STOP key

DSO

Manually turns on (run) or off (stop) the 
trigger. For details, see page

88H

25. 

RUN/STOP key

DMM

Freezes (stop) or unfreezes (run) the 
measurement. 

AUTOSET key

DSO

Automatically selects the horizontal scale, 
vertical scale, and trigger level according 
to the input signal. See page

89H

18 for details. 

DMM

Switches the measurement mode. For 
details, see page

90H

87(current), 

page

91H

85(voltage), and page

92H

89(impedance). 

DMM/OSC key

Switches the operation mode between the 
oscilloscope and multimeter. 

CH1/2 terminal

DSO

Accepts the CH1 and CH2 input signal. 

CX terminal

DMM

Accepts the test leads for capacitor 
measurement. 

V/Ω terminal

DMM

Accepts the red lead for voltage, small 
capacitance, and impedance 
measurements. 

COM terminal

DMM

Accepts the black (ground) lead. 

mA terminal

DMM

Accepts the red lead for current 
measurement. 

R switch

DMM

Selects the following measurement: 
impedance (page

93H

89), diode (page

94H

91), 

continuity (page

95H

92), capacitance (page

96H

93). 

V switch

DMM

Selects voltage measurements (page

97H

85). 

A switch

DMM

Selects current measurements (page

98H

87). 

Power switch

Turns on or off the GDS‐122 power. 

F1 – F5 keys

Selects the menu item at the bottom of the display. 

Disp contrast sw

Selects the display contrast. 

GDS-122 User Manual

14

3B

Manual Overview

Overview

This user manual is comprised of seven chapters. 
If you want to jump start using the GDS‐122, go 
directly to the Using Oscilloscope or Using 
Multimeter
 chapter. 

Safety

Instructions

(page

99H

6)

The Safety Instructions gives you an overview of 
important safety‐related issues which you should 
be aware of before, during, and after operations. 

Getting Started

(page

100H

9)

The Getting Started chapter provides you with the 
overview of the GDS‐122: main features, package 
contents, front panel, and user manual (this 
section). 

Using the

Oscilloscope

(page

101H

15)

The Using the Oscilloscope chapter describes in 
detail how to use the GDS‐122’s oscilloscope 
functionalities, including the PC software. The 
chapter starts with simple, basic operations 
toward more complex measurements and settings. 
If you are new to the GDS‐122, start with the Basic 
Operations section. For advanced users, the Menu 
Tree / Shortcuts
 section shows the menu structures 
and all operations shortcuts. 

Using the

Multimeter

(page

102H

83)

The Using the Multimeter chapter describes how to 
use the GDS‐122’s multimeter functionalities. The 
most commonly used Voltage, Current, and 
Resistance sections are listed in the front. 

Faq
(page

103H

95)

The Faq chapter lists major problems you might 
encounter during operations and how to fix or 
avoid them. Most issues are also listed in the 
relevant chapters throughout the document. 

Specifications

(page

104H

97)

The GDS‐122 specifications are separated in 
oscilloscope, multimeter, and general parts. 

Declaration of

conformity

(page

105H

100)

The Declaration of Conformity chapter lists the 
safety and EMI/EMC standards to which the GDS‐
122 conforms. 

Index
(page

106H

101)

The Index chapter lists most of the keywords used 
in this manual in an alphabetical order.