Ndex – GW Instek GDS-122 User Manual User Manual
Page 51

Index
101
I
NDEX
AC coupling
trigger ............................................. 32
vertical............................................ 24
ACA multimeter ................................ 87
specifications ................................. 99
AC‐DC adaptor.................................. 10
acquisition........................................... 35
short cuts........................................ 58
system status ................................. 37
ACV multimeter ................................ 85
specifications ................................. 98
addition, math mode......................... 39
auto ranging
impedance multimeter ................ 89
voltage multimeter ....................... 86
auto trigger mode.............................. 31
AUTO trigger status.......................... 27
automatic measurements ................. 41
shortcuts......................................... 57
Autoset ................................................ 18
capacity multimeter ..................... 93
continuity, multimeter................. 92
diode, multimeter......................... 91
impedance measurement ............ 89
voltage multimeter ....................... 85
average acquisition mode ................ 35
application ..................................... 49
background color, PC software....... 68
battery level ........................................ 16
calibration ........................................... 51
short cuts........................................ 58
capacitance measurement,
multimeter ..................................... 93
specifications ................................. 99
carry, interface setting ...................... 66
carrying case....................................... 10
caution symbol..................................... 6
CD‐ROM ............................................. 10
channel
edge trigger ................................... 31
on/off .............................................. 23
video trigger source ..................... 34
contents of package ........................... 10
continuity, multimeter...................... 92
specifications ................................. 99
coupling
system status ................................. 38
trigger ............................................. 32
vertical............................................ 24
cursor measurement
PC software ................................... 75
short cuts........................................ 57
time ................................................. 42
voltage ............................................ 43
cycle rms, automatic measurement 41
data point, storing ............................. 77
data table, PC software..................... 77
DC coupling
trigger ............................................. 32
vertical............................................ 24
DCA multimeter ................................ 87
specifications ................................. 98
DCV multimeter ................................ 85
specifications ................................. 98
default settings................................... 53
delta measurement
capacitance multimeter ............... 94
current multimeter ....................... 88
impedance multimeter ................ 90
voltage multimeter....................... 86
diode measurement, multimeter..... 91
specifications ................................. 99
display
acquiring snapshot ....................... 67
brightness adjustment ................. 16
overview ........................................ 19
GDS-122 User Manual
102
settings ........................................... 36
shortcuts......................................... 58
specifications ................................. 99
division, math mode ......................... 39
dot drawing ........................................ 36
edge trigger......................................... 30
auto mode ...................................... 31
coupling mode .............................. 32
mode ............................................... 31
normal mode ................................. 32
single mode ................................... 32
EN61000 ............................................ 100
EN61010
declaration of conformity.......... 100
measurement category .................. 7
pollution degree.............................. 7
EN61326‐1......................................... 100
environment
operation .......................................... 7
specifications ................................. 99
storage .............................................. 8
ERR mode, multimeter ..................... 95
extension module
capacitance multimeter................ 93
current multimeter ....................... 88
package .......................................... 10
factory settings ................................... 53
FAQ...................................................... 95
ERR mode, multimeter ................ 95
magnification ................................ 95
no waveform ................................. 96
powering up .................................. 95
slow update, multimeter ............. 96
slow update, oscilloscope............ 96
unstable waveform....................... 95
field trigger, video............................. 34
freezing measurement
capacitance multimeter................ 94
continuity multimeter.................. 92
current multimeter ....................... 88
diode multimeter.......................... 91
impedance multimeter ................ 90
voltage multimeter ....................... 86
frequency, automatic measurement41
front panel overview......................... 12
grid color, PC software ..................... 69
grid, PC software............................... 69
ground symbol..................................... 6
help, PC software .............................. 82
Hf Rjc ................................................... 32
horizontal
adjusting position................... 20, 25
adjusting scale......................... 19, 26
scale vs trigger status................... 28
short cuts........................................ 58
specifications ................................. 97
system status ................................. 37
impedance, multimeter..................... 89
specifications ................................. 99
installing PC software....................... 62
inverting channel............................... 24
language
PC software ................................... 70
short cuts........................................ 58
LF Rjc ................................................... 32
line data, PC software....................... 69
line trigger, video .............................. 34
list of features ..................................... 11
magnification, vertical ...................... 25
manual ranging
current multimeter ....................... 88
impedance multimeter ................ 90
voltage multimeter ....................... 86
manual, overview of ......................... 14
math mode.......................................... 39
shortcuts......................................... 57
system status ................................. 38
mean voltage, auto measurement... 41
multimeter
activating ....................................... 84
capacitance measurement ........... 93
continuity measurement ............. 92
current measurement................... 87
diode measurement...................... 91
ERR mode ...................................... 95
impedance measurement ............ 89
specifications ................................. 98
voltage measurement................... 85
warning message.......................... 84
multiplication, math mode .............. 39
noisy signal, viewing ........................ 49
normal trigger mode ......................... 32