beautypg.com

Job issues – Seed Hawk Raven 2011 User Manual

Page 201

background image

11

Manual No. 016-3001-003

191

Troubleshooting the Viper Pro System

Job Issues

Issue

Possible Cause

Solution

Section numbers
are gray

• Section switches are

turned off

• Turn section and master switch on.

• SCT enabled but

machine not moving

• Move the machine out of the applied zone.

• CAN is disconnected

• See the CAN Troubleshooting section.

Section number
does not turn green
when turned on

• The section is not set up

properly

• Check the section setup from the Setup menu.

• Nodes not completely

programmed

• Check Node calibration and ensure all calibration is completed.

• The section is

disconnected

• Check the connection and wiring to the section.

SCT system will not
turn on

• Section switches are in

the 'Off' position

• Section switches must be in the 'SCT' position.

INC/DEC function
switch does not
work

• INC/DEC not enabled for

appropriate product(s)

• Assign INC/DEC switch function to the appropriate product(s).

• Product application is

turned off

• Switch product application to either auto or manual mode.

Dates and time are
incorrect

• No GPS

• Make sure that the GPS receiver is operating properly and that

there is a green 'thumbs-up' icon displayed in the GPS section of
the main screen.

• No GPS RMC or ZDA

• Check the GPS receiver to make sure the RMC or ZDA string is

selected.

• Incorrect time zone

selected

• Verify the time zone selected in the Menu/Setup/Local/Time

Zone section.

Product applied in
zero rate zones

• SCT Ready system

• SCT Ready system cannot turn off granular products

independently.

• Wrong valve type on

vehicle

• Must use either a Fast Close or PWM Close valve (not available

for ground drive air carts).

• Incorrect valve setting

• Check valve or PWM setting.