Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual
Page 28

Blade
Port numbering
Trunking port groups
FC8-48E port
blade
• 0 through 23 from right to left on the lower set of
ports.
• 24 through 47 from right to left on the upper set of
ports.
• 0-7, 8-15, 16-23, 24-31, 32-39,
40-47.
FC8-64 port
blade
• 0 through 31 from right to left on the lower set of
ports.
• 32 through 63 from right to left on the upper set of
ports.
• 0-7, 8-15, 16-23, 24-31, 32-39,
40-47, 48-55, and 56-63.
FC16-32 port
blade
• 0 through 15 from right to left on the lower set of
ports.
• 16 through 31 from right to left on the upper set of
ports.
• 0-7, 8-15, 16-23, and 24-31.
FC16-48 port
blade
• 0 through 23 from right to left on the lower set of
ports.
• 24 through 47 from right to left on the upper set of
ports.
• 0-7, 8-15, 16-23, 24-31, 32-39,
40-47.
FC16-64 port
blade
• 0 through 63 from right to left.
These are QSFP ports 0-15. For supported QSFPs,
refer to
Qualified transceivers for the FC16-64 port
• 0-7, 8-15, 16-23, 24-31, 32-39,
40-47, 48-55, and 56-63.
CR16-4 core
blade
• ICL connectors are numbered from 0 through 7 from
right to left .
Each connector is a group of four 16-Gbps ports. For
supported QSFPs, refer to
the FC16-64 port blade and the core blades
40
• Trunk group 0: FC ports 0-3
• Trunk group 1: FC ports 4-7
NOTE
Individual FC ports within the same
QSFP port cannot form a trunk. A
trunk has to comprise of individual
FC ports from different consecutive
QSFP ports. Only four FC ports from
consecutive QSFP ports can form a
trunk in Brocade DCX 8510-4
FS8-18 blade
• The 16 physical Fibre Channel ports on this blade
are numbered 0 through 15 from right to left.
• The two 10/100/1000 BaseT ports are numbered
from the bottom as GE0 and GE1.
• 0-7 and 8-15.
FX8-24 blade
Ports are numbered in groups.
• The FC ports are numbered from 0 through 11 in two
horizontal rows of six ports starting from the lower
right and upper right in the right group of 12 ports.
They are labeled FC on the front panel diagram.
• The two 10-GbE ports are 0 and 1 and are in the
lower row to the left of the FC ports. They are labeled
10GE on the front panel diagram.
• The GbE ports are numbered 0 through 9 and are in
both rows to the left of the FC and 10GE ports. They
are labeled GE on the front panel diagram.
Up to three FC trunking groups are
permitted. The three groups are
defined as follows:
• Trunk group 0: FC ports 0, 1
• Trunk group 1: FC ports 6, 7
• Trunk group 2: FC ports 2, 3, 4, 5,
8, 9, 10, 11
Installation of the Brocade DCX 8510-4
28
Brocade DCX 8510-4 Backbone Hardware Reference Manual
53-1002177-07