Configuration download at an encryption group member node
Switch specific configuration information pertaining to the member switch or blade is applied.
Information specific to the encryption group leader is filtered out.
Steps after configuration download
For all opaque key vaults, restore or generate and backup the master key. In a multiple node
encryption group, the master key is propagated from the group leader node.
1. Use the following command to enable the encryption engine.
Admin:switch> cryptocfg --enableEE [slot num]
2. Commit the configuration.
Admin:switch> cryptocfg --commit
3. If there are containers that belonged to the old encryption switch or blade, then after
configdownload is run, use the following command to change the ownership of containers to
the new encryption switch or blade, assuming the host and target physical zone exists.
Admin:switch> cryptocfg --replace
4. Commit the configuration.
Admin:switch> cryptocfg --commit
5. Use the following command to check if the switch or blade has the master key.
Admin:switch> cryptocfg --show -groupmember
6. If a master key is not present, restore the master key from backed up copy. Procedures will
differ depending on the backup media used (from recovery smart cards, from the key vault,
from a file on the network or a file on a USB-attached device). If new master key needs to be
generated, generate the master key and back it up.
For LKM/SSKM key vaults, establish the trusted link with the LKM/SSKM appliance.
If authentication cards are used, set the authentication quorum size from the encryption group
leader node after importing and registering the necessary number of Authentication Card
certificates.
HP-UX considerations
The HP-UX OS requires LUN 0 to be present. LUNs are scanned differently based on the type value
returned for LUN 0 by the target device.
•
If the type is 0, then HP-UX only scans LUNs from 0 to 7. That is the maximum limit allowed by
HP-UX for device type for type 0.
•
If the type is 0xC, then HP-UX scans all LUNs.