beautypg.com

Regulatory compliance, Power source interruptions, Figure 25 – Brocade TurboIron 24X Series Hardware Installation Guide User Manual

Page 61

background image

Brocade TurboIron 24X Series Hardware Installation Guide

51

53-1002981-01

Device specifications

A

FIGURE 25

Device air flow

Total cooling capacity: 200 watts

Total air flow: 150 LFM

Fan operating noise: < 65 dB-A.

NOTE

Operating noise is based on the ISO 7779 standard.

Regulatory compliance

Table 9

lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency

approvals for TurboIron 24X switches.

Power source interruptions

Table 10

shows how the TurboIron 24X protects against power surges and power drops.

1

Left intake

3

Right intake

2

Front intakes

4

Exhaust

TABLE 9

Device regulatory compliance

Description

Certifications

Electromagnetic Emissions

CISPR-22 Class A

EN 55022

FCC Class A (Part 15)

VCCI Class A

Immunity

EN 50024:1998

Safety

EN 60950-1

CAN/CSA C22.2 No. 60950-1-03

EN 60825-1, Safety of Laser Products - Part 1

EN 60825-2, Safety of Laser Products - Part 2

IEC 60950-1

UL 60950-1

1

2

3

4