Managing temperature settings

4

Fan speed switching temperature thresholds:
Speed 1: NM<----->30 deg-C
Speed 2: 25<----->40 deg-C
Speed 3: 35<----->90 deg-C (shutdown)

Boot Prom MAC: 00-00-00
TurboIron#

Displaying temperature messages

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning
threshold. The following methods describe how to view the system log on the device. If you have
configured the device to use a Syslog server or SNMP trap receiver, refer to the documentation for
the server or receiver.

To display the system log, enter the following command at any CLI level.

TurboIron# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 50.0 C degrees, warning level 45.0 C degrees

Changing the temperature warning level

The default warning temperature is 45.0 C degrees. You can change the warning temperature
using the temperature warning command. The valid range is 0 - 125 C degrees.

TurboIron 24X devices automatically reset and reload the software when the internal temperature
reaches or exceeds the configured shutdown level for five minutes. The TurboIron 24X has the
capability to register negative temperature settings.

To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.

TurboIron# temperature warning 47

Syntax: temperature warning value

NOTE

The value can be 0 - 125.

Changing the device temperature polling interval

The software reads the temperature sensor and polls other hardware sensors according to the
value set for the device poll time, which is 60 seconds by default. You can change the device poll
time using the CLI.