Yokogawa FVX110 User Manual
Page 76

<12. Parameter Lists>
12-3
IM 01S01C01-01EN
Relative
Index Index
Parameter Name
Factory Default Write
Mode
Explanation
54
1054
SOFTDWN_FORMAT 0x01
AUTO Selects the software download method.
0x01: Standard
0x02: YOKOGAWA Standard
55
1055
SOFTDWN_COUNT
0
—
Indicates the number of times the internal FlashROM was
erased.
56
1056
SOFTDWN_ACT_
AREA
0
—
Indicates the ROM number of the currently working FlashROM.
0: FlashROM #0 working
1: FlashROM #1 working
57
1057
SOFTDWN_MOD_
REV
1, 0, 0, 0, 0, 0,
0, 0, 0
—
Indicates the software module revision.
58
1058
SOFTDWN_ERROR 0
—
Indicates the error during a software download.
Refer Table A8.4.
59
1059 SOFTDWN_HISTORY
—
Not used by the FVX110.
60
1060 SOFTDWN_HIST_INDEX
0
AUTO
Not used by the FVX110.
61
1061 COMPATIBILITY_REV 1
—
Indicates the smallest Rev value compatible with device
DevRev.
62
1062 CAPABILITY_LEV
0x00
—
Indicates the capability level of instrument interior.
63
1063 CAPABILITY_CONFIG
0x0000
—
A parameter corresponding to AP_CONF or DEV_OPTIONS
before the addition of parameter CAPABILITY_LEV.
64
1064 WRITE_LOCK_LEVEL
2
AUTO
Specifies blocks that activates Write Lock.
65
1065 SI_CONTROL_CODES
1
—
A parameter for switching to make the instrument compatible
with SI units.
66
1066 FD_VER
0
—
Indicates value of major version of instrument diagnostics
specifications (FF-912).
67
1067 FD_FAIL_ACTIVE
0
—
A parameter that corresponds to ”Failed” in the NAMUR NE-
107 category.
68
1068 FD_OFFSPEC_ACTIVE 0
—
A parameter that corresponds to ”Off Specification” in the
NAMUR NE-107 category.
69
1069 FD_MAINT_ACTIVE
0
—
A parameter that corresponds to ”Maintenance” in the NAMUR
NE-107 category.
70
1070 FD_CHECK_ACTIVE 0
—
A parameter that corresponds to ”Check Function” in the
NAMUR NE-107 category.
71
1071 FD_FAIL_MAP
0xFC000000
AUTO
Specifies the bit assigned to FD_FAIL_ACTIVE, a parameter
for indicating ”Failed,” a 32-bit alarm listed in FD_SIMULATE.
DiagnosticValue.
72
1072 FD_OFFSPEC_MAP
0x00003800
AUTO
Specifies the bit assigned to FD_OFFSPEC_ACTIVE, a
parameter for indicating ”Off Specification,” a 32-bit alarm listed
in FD_SIMULATE. DiagnosticValue.
73
1073 FD_MAINT_MAP
0x000003E0
AUTO
Specifies the bit assigned to FD_MAINT_ACTIVE, a parameter
for indicating ”Maintenance,” a 32-bit alarm listed in FD_
SIMULATE. DiagnosticValue.
74
1074 FD_CHECK_MAP
0x01FF8008
AUTO
Specifies the bit assigned to FD_CHECK_ACTIVE, a
parameter for indicating ”Check Function,” a 32-bit alarm listed
in FD_SIMULATE. DiagnosticValue.
75
1075 FD_FAIL_MASK
0xFFFFFFFF
AUTO
Specifies the bit that notifies the host of 32-bit ”Failed” alarms
listed in FD_FAIL_ACTIVE.
76
1076 FD_OFFSPEC_MASK 0xFFFFFFFF
AUTO
Specifies the bit that notifies the host of 32-bit ”Off
Specification” alarms listed in FD_OFFSPEC_ACTIVE.
77
1077 FD_MAINT_MASK
0xFFFFFFFF
AUTO
A parameter that specifies the bit that notifies the host of
32-bit ”Maintenance” alarms listed in FD_MAINT_ACTIVE. A
parameter set by the user.
78
1078 FD_CHECK_MASK
0xFFFFFFFF
AUTO
Specifies the bit that notifies the host of 32-bit ”Check Function”
alarms listed in FD_CHECK_ACTIVE.
79
1079 FD_FAIL_ALM
AUTO
Indicates alarm information for alarms categorized under
”Failed.”
80
1080 FD_OFFSPEC_ALM
AUTO
Indicates alarm information for alarms categorized under ”Off
Specification.”
81
1081 FD_MAINT_ALM
AUTO
Indicates alarm information for alarms categorized under
”Maintenance”.
82
1082 FD_CHECK_ALM
AUTO
Indicates alarm information for alarms categorized under
”Check Function”.
83
1083 FD_FAIL_PRI
0
AUTO
Indicates the FD_FAIL_ALM priority for an alarm.
84
1084 FD_OFFSPEC_PRI
0
AUTO
Indicates the FD_OFFSPEC_ALM priority for an alarm.
85
1085 FD_MAINT_PRI
0
AUTO
Indicates theFD_MAINT_ALM priority for an alarm.