beautypg.com

Warning – Yokogawa FVX110 User Manual

Page 22

background image

<2. Handling Cautions>

2-12

IM 01S01C01-01EN

Note 2. Electrical Data

• Supply voltage: 32 V dc max.

Output current: 15 mA dc

Note 3. Installation

• All wiring shall comply with local installation

requirements.

• The cable entry devices shall be of a certified

flameproof type, suitable for the conditions of

use.

Note 4. Operation

• Keep the “WARNING” label attached to the

indicator.

WARNING: AFTER DE-ENERGIZING,

DELAY 5 MINUTES BEFORE OPENING.

WHEN THE AMBIENT TEMP.≥65ºC, USE

HEAT-RESISTING CABLES≥90ºC.

• Take care not to generate mechanical

sparking when accessing the instrument and

peripheral devices in hazardous location.

Note 5. Maintenance and Repair

• The instrument modification or part

replacement by other than an authorized

representative of Yokogawa Electric

Corporation is prohibited and will void KEMA

Flameproof Certification.

(2) Electrical Connection
A mark indicating the electrical connection type is

stamped near the electrical connection port. These

marks are as follows.

F0211.ai

Location of the mark

ISO M20

×

1.5 female

ANSI 1/2 NPT female

Marking

Screw Size

A or W

M

(3) Installation

WARNING

• All wiring shall comply with local installation

requirements and the local electrical code.

• There is no need for a conduit seal in

Division 1 and Division 2 hazardous

locations because this product is sealed at

the factory.

The grounding terminals are located on the inside

and outside of the terminal area.

Connect the cable to grounding terminal in

accordance with wiring procedure 1) or 2).

2) Internal grounding

terminal

1) External grounding

terminal

F0212.ai

Wiring Procedure for Grounding Terminals

(4) Operation

WARNING

• OPEN CIRCUIT BEFORE REMOVING

COVER. INSTALL IN ACCORDANCE WITH

THIS USER’S MANUAL

• Take care not to generate mechanical

sparking when accessing the instrument and

peripheral devices in a hazardous location.

(5) Maintenance and Repair

WARNING

The instrument modification or part replacement

by other than an authorized Representative of

Yokogawa Electric Corporation is prohibited and

will void the certification.