Yokogawa digitalYEWFLO (DY-FF) User Manual
Page 29
<5. CONFIGURATION>
5-12
IM 01F06F00-01EN
Relative
Index
Parameter
Mnemonic
VIEW_
1
VIEW_
2
VIEW_
3
VIEW_
4
1
ST_REV
2
2
2
2
2
TAG_DESC
3
STRATEGY
2
4
ALERT_KEY
1
5
MODE_BLK
4
4
6
BLOCK_ERR
2
2
7
PV
5
5
8
SP
5
5
9
OUT
5
5
10
PV_SCALE
11
11
OUT_SCALE
11
12
GRANT_DENY
2
13
CONTROL_OPTS
2
14
STATUS_OPTS
2
15
IN
5
16
PV_FTIME
4
17
BYPASS
1
18
CAS_IN
5
5
19
SP_RATE_DN
4
20
SP_RATE_UP
4
21
SP_HI_LIM
4
22
SP_LO_LIM
4
23
GAIN
4
24
RESET
4
25
BAL_TIME
4
26
RATE
4
27
BKCAL_IN
5
28
OUT_HI_LIM
4
29
OUT_LO_LIM
4
30
BKCAL_HYS
4
31
BKCAL_OUT
5
32
RCAS_IN
5
33
ROUT_IN
5
34
SHED_OPT
1
35
RCAS_OUT
5
36
ROUT_OUT
5
37
TRK_SCALE
11
38
TRK_IN_D
2
2
39
TRK_VAL
5
5
40
FF_VAL
5
Relative
Index
Parameter
Mnemonic
VIEW_
1
VIEW_
2
VIEW_
3
VIEW_
4
41
FF_SCALE
11
42
FF_GAIN
4
43
UPDATE_EVT
44
BLOCK_ALM
45
ALARM_SUM
8
8
46
ACK_OPTION
2
47
ALARM_HYS
4
48
HI_HI_PRI
1
49
HI_HI_LIM
4
50
HI_PRI
1
51
HI_LIM
4
52
LO_PRI
1
53
LO_LIM
4
54
LO_LO_PRI
1
55
LO_LO_LIM
4
56
DV_HI_PRI
1
57
DV_HI_LIM
4
58
DV_LO_PRI
1
59
DV_LO_LIM
4
60
HI_HI_ALM
61
HI_ALM
62
LO_ALM
63
LO_LO_ALM
64
DV_HI_ALM
65
DV_LO_ALM
Total bytes
43
43
83
104
Table 5.15
View Objects for PID Function Block (option /LC1)