Setting requirement
A: Required (function selection)
B: Required (network environment, etc.)
C: Checked (As a rule, the default value
on the parameter list must be used.)
Modbus/
TCP
IAI protocol
B/TCP
Transmission by
SEL program
No. Parameter
name
Default value
(reference)
Input range
Unit
Remarks
B B
B 133
Own IP address
(MH)
168 0~255
B B
B 134
Own IP address
(ML)
0 0~255
B B
B 135 Own IP address (L)
1
1~254
* Setting of “0” and “255” is prohibited.
B B
B 136 Subnet mask (H)
255
0~255
B B
B 137 Subnet mask (MH)
255
0~255
B B
B 138 Subnet mask (ML)
255
0~255
B B
B 139 Subnet mask (L)
0
0~255
B B
B 140 Default gateway (H)
0
0~255
B B
B 141
Default gateway
(MH)
0 0~255
B B
B 142
Default gateway
(ML)
0 0~255
B B
B 143 Default gateway (L)
0
0~255
C
144
IAI protocol B/TCP:
Own port number
(MANU mode)
64511 1025~65535
C
145
User-open channel
31 (TCP/IP): Own
port number
64512 1025~65535
C
146
User-open channel
32 (TCP/IP): Own
port number
64513 1025~65535
C
147
User-open channel
33 (TCP/IP): Own
port number
64514 1025~65535
C
148
User-open channel
34 (TCP/IP): Own
port number
64515 1025~65535
* Important note: Be sure to set a unique number for each
own port number.
(The duplication of own port numbers is permitted only in
the IAI protocol B/TCP MANU/AUTO modes.)