IAI America XSEL Ethernet User Manual
Page 32

- 26 -
138
Subnet mask (ML)
255
0~255
139
Subnet mask (L)
0
0~255
140
Default gateway (H)
0
0~255
141
Default gateway (MH)
0
0~255
142
Default gateway (ML)
0
0~255
143
Default gateway (L)
0
0~255
…
…
…
…
…
149
IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(H)
192
1~255
* Setting of “0” and “127” is prohibited.
150
IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(MH)
168 0~255
151
IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(ML)
0 0~255
152
IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(L)
100
1~254
* Setting of “0” and “255” is prohibited.
153
IAI protocol B/TCP: Port
number of connection
destination (MANU mode)
64611 0~65535
Mode setting in parameter No. 124:
* In the server mode “0” can be set.
0 = Ignore port number of connection destination
(Only the IP address is checked.)
* In the client mode “0” cannot be set.
154
IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(H)
192
1~255
* Setting of “0” and “127” is prohibited.
155
IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(MH)
168 0~255
156
IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(ML)
0 0~255
157
IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(L)
100 1~254
* Setting of “0” and “255” is prohibited.
158
IAI protocol B/TCP: Port
number of connection
destination (AUTO mode)
64611 0~65535
Mode setting in parameter No. 124:
* In the server mode “0” can be set.
0 = Ignore port number of connection destination
(Only the IP address is checked.)
* In the client mode “0” cannot be set.
(Note) 1. To connect the controller to IAI’s PC software, set the parameter to “1: Client (Assign own port number
automatically.”
2. IAI’s PC software will detect “Error No. ECF: Socket error (PC)” if the controller-side port is disabled due to
a mode change on the controller side, reception of an IAI protocol serial-communication message or other
reason while the controller is connected to the PC software. This does not indicate abnormal status.
3. The connection will be cut off briefly during switching between the MANU and AUTO modes under IAI
protocol B/TCP, if the parameter settings of “own port number,” “client/server type,” “IP address of
connection destination” and “port number of connection destination” do not fully correspond between the
two modes.