IAI America XSEL Ethernet User Manual

Page 51

background image

- 45 -

Appendix: X-SEL (Cartesian/IX SCARA) Ethernet Option Parameters

[I/O parameters]

Setting requirement
A: Required (function selection)
B: Required (network environment, etc.)
C: Checked (As a rule, the default value

on the parameter list must be used.)

Modbus/

TCP

IAI protocol

B/TCP

Transmission by

SEL program

No. Parameter

name

Default

value

(reference)

Input range

Unit

Remarks

A

C C

1

I/O port
assignment type

1 0~20

0: Fixed assignment
I/O numbers are specified by parameters.
1: Automatic assignment (priority sequence: slot 1~)

A

C C

2

Standard I/O
input-port start
number (I/O1)

0 -1~599

0 + (Multiple of 8) (A negative value is invalid.)
0: Assign Modbus/TCP remote DIs from No. 0.

A

C C

3

Standard I/O
output-port start
number (I/O1)

300 -1~599

300 + (Multiple of 8) (A negative value is invalid.)
300: Assign Modbus/TCP remote DOs from No. 300.

A

C C

4

Expanded I/O1
input-port start
number based on
fixed assignment
(I/O2)

-1 -1~599

0 + (Multiple of 8) (A negative value is invalid.)
-1: No expanded I/O1 DI

A

C C

5

Expanded I/O1
output-port start
number based on
fixed assignment
(I/O2)

-1 -1~599

300 + (Multiple of 8) (A negative value is invalid.)
-1: No expanded I/O1 DO

A

C C

6

Expanded I/O2
input-port start
number based on
fixed assignment
(I/O3)

-1 -1~599

0 + (Multiple of 8) (A negative value is invalid.)
-1: No expanded I/O2 DI

A

C C

7

Expanded I/O2
output-port start
number based on
fixed assignment
(I/O3)

-1 -1~599

300 + (Multiple of 8) (A negative value is invalid.)
-1: No expanded I/O2 DO