- 14 -

4. Remote I/O (Modbus/TCP

EtherNet/IP)

4.1

Setup of Ethernet Environment

The X-SEL controller provides IP addresses and other network-definition areas in its I/O parameters
for control of Modbus/TCP

 EtherNet/IP operation.

Set the necessary parameters according to the network environment before connecting to the network.
Establishing a connection without setting the parameters may disable normal communication to and
from other devices on the network.

* EtherNet/IP is supported only by X-SEL controllers of P/Q types (main application version 1.05 or

later). Also note that to use EtherNet/IP, you need an interface board compatible with EtherNet/IP.

[I/O parameters]

No. Parameter

name Setting

Input

range

Remarks

129 Network attribute 10

1H

0H~FFFFFFFFH

Ethernet operation requirement

Bits 0 to 3: Remote I/O

0: Do not use
1: Use Modbus/TCP (EXCEPTION status invalid)
2: Use Modbus/TCP (EXCEPTION status valid)
3: Use EtherNet/IP (main application version 1.05 or

later)

Bits 4 to 7: TCP/IP message communication

(0: Do not use, 1: Use)

Bits 8 to 31: Not used

130

Own MAC address (H)

0030H

Reference value

(HEX)

Only the lower two bytes are valid. (This parameter is not
settable.)

131 Own MAC address (L)

11H

Reference value

(HEX)

(This parameter is not settable.)

132 Own IP address (H)

192

1~255

* Setting of “0” and “127” is prohibited.

133 Own IP address (MH)

168

0~255

134 Own IP address (ML)

0

0~255

135 Own IP address (L)

1

1~254

* Setting of “0” and “255” is prohibited.

136 Subnet mask (H)

255

0~255

137 Subnet mask (MH)

255

0~255

138 Subnet mask (ML)

255

0~255

139 Subnet mask (L)

0

0~255

140 Default

gateway

(H)

0

0~255

141 Default

gateway

(MH)

0

0~255

142 Default

gateway

(ML)

0

0~255

143 Default

gateway

(L)

0

0~255


(Note)

1. Always set I/O parameter No. 129 to “1” to perform Modbus/TCP

 EtherNet/IP operation.

2. The Modbus/TCP port number on the controller side is fixed at “502.”

3. 44818 or 2222 is used for the EtherNet/IP port number on the controller side.