IAI America NS User Manual
Page 42

28
6SHFL¿FDWLRQV
Model
Unit
LXMXS, horizontal specification
LZMS, vertical
specification
LZMM, vertical
specification
Lead
0
2
0
2
0
4
0
2
Stroke
mm
2300 to 3000
2300 to 3000
500 to 1000
250 to 950
Rated thrust
N
340.1
170.0
340.1
340.1
Maximum speed
mm/sec
1300
2400
1000
1000
Rated acceleration*3
G
0.3
0.3
0.3
0.3
Maximum
acceleration/deceleration*3
G
0.3
0.3
0.8
0.8
Loading capacity at rated
acceleration*2
kgf
80
(When used
horizontally)
40
(When used
horizontally)
16
(When used
vertically)
16
(When used
vertically)
Loading capacity at
maximum acceleration*2
kgf
80
(When used
horizontally)
40
(When used
horizontally)
6
(When used
vertically)
6
(When used
vertically)
Positioning repeatability
mm
r0.01
r0.01
r0.01
r0.01
Ma: 104.9 (107)
Ma: 104.9 (107)
Ma: 104.9 (107)
Ma: 104.9 (107)
Mb:104.9 (15.3)
Mb:104.9 (15.3)
Mb:104.9 (15.3)
Mb:104.9 (15.3)
Load moment
*1
N. m
(kgf cm)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Ma direction:
750 max.
Ma direction:
750 max.
Ma direction:
750 max.
Ma direction:
750 max.
Overhang load length
mm
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
*1
Based on an acceleration of 0.3 G and the maximum speed.
*2
The maximum speed is assumed.
*3
The table below shows the relationship of acceleration/deceleration and loading capacity.
These values are not guaranteed and should be used only as a guide.
Even when the acceleration is equal to or below the rated acceleration, the loading capacity remains the same
as the value at the rated acceleration.
As for actuator types with mid-support, the maximum acceleration is the same as the rated acceleration.
Accordingly, the loading capacity at the maximum acceleration corresponds to the loading capacity at the rated
acceleration.
Loading capacity by acceleration (kg)
Type
Lead
Maximum speed
0.3G
0.4G
0.5G
0.6G
0.7G
0.8G
LZMS
LZMM
20 mm
1000 mm/sec
16
12.3
11.1
10.1
9.2
6
LXMXS
20 mm
1300 mm/sec
80
40 mm
2400 mm/sec
40
Caution:
x Use each actuator by observing its maximum speed.
x Take note that resonance may still occur at speeds below the applicable limit specified
above, depending on the installation condition or operating conditions.
x Resonance of the ball screw shaft may increase the noise level or cause vibration,
resulting in a shorter service life of the machine.
x If each actuator is used independently, write a program conforming to the maximum
speed of the actuator (refer to the table above). If multiple actuators are used in a
synchronized operation, write a program conforming to the lowest of the maximum
speeds applicable to all synchronized actuators.
x In either way, always check the maximum speed of each applicable actuator when writing
a program.
г
г
г
г
г
г
г
г
г
г