Specifications, 1 small type – IAI America NS User Manual
Page 38

24
6SHFL¿FDWLRQV
6. Specifications
6.1 Small
type
Model Unit
SXMS, horizontal
specification
SXMM, horizontal
specification
SZMS,
vertical
specification
SZMM,
vertical
specification
Lead
12 12 12 12
Stroke
mm
400 to 800
230 to 830
420 to 820
220 to 820
Rated
thrust
N
70.8 70.8 70.8 70.8
Maximum speed
mm/sec
720 720 600 600
Rated acceleration
*3
G 0.3 0.3 0.3 0.3
Maximum
acceleration/deceleration
*3
G 0.8 0.8 0.7 0.7
Loading capacity at rated
acceleration
*2
kgf
15
(When used
horizontally)
15
(When used
horizontally)
3
(When used
vertically)
3
(When used
vertically)
Loading capacity at
maximum acceleration
*2
kgf 0.5 0.5 0.5 0.5
Positioning repeatability
mm
r0.02
r0.02
r0.02
r0.02
Ma: 28.4 (2.9)
Ma: 28.4 (2.9)
Ma: 28.4 (2.9)
Ma: 28.4 (2.9)
Mb: 40.2 (4.1)
Mb: 40.2 (4.1)
Mb: 40.2 (4.1)
Mb: 40.2 (4.1)
Load moment
*1
N. m
(kgf
ycm)
Mc: 65.7 (6.7)
Mc: 65.7 (6.7)
Mc: 33.3 (3.4_
Mc: 33.3 (3.4_
Ma direction: 450
max.
Ma direction: 450
max.
Ma direction: 450
max.
Ma direction: 450
max.
Overhang load length
mm
Mb/Mc directions:
450 max.
Mb/Mc directions:
450 max.
Mb/Mc directions:
450 max.
Mb/Mc directions:
450 max.
*1
Based on an acceleration of 0.3 G and the maximum speed.
*2
The maximum speed is assumed.
*3
The table below shows the relationship of acceleration/deceleration and loading capacity.
These values are not guaranteed and should be used only as a guide.
Even when the acceleration is equal to or below the rated acceleration, the loading capacity remains the same
as the value at the rated acceleration.
Loading capacity by acceleration (kg)
Type Lead
Maximum
speed
0.3G 0.4G 0.5G 0.6G 0.7G 0.8G
SXMS
SXMM
12 mm
720 mm/sec
15
7
5
3
1
0.5
SZMS
SZMM
12
mm 600
mm/sec 3 2 1.5 1 0.5
Caution:
x Use each actuator by observing its maximum speed.
x Take note that resonance may still occur at speeds below the applicable limit specified
above, depending on the installation condition or operating conditions.
x Resonance of the ball screw shaft may increase the noise level or cause vibration,
resulting in a shorter service life of the machine.
x If each actuator is used independently, write a program conforming to the maximum
speed of the actuator (refer to the table above). If multiple actuators are used in a
synchronized operation, write a program conforming to the lowest of the maximum
speeds applicable to all synchronized actuators.
x In either way, always check the maximum speed of each applicable actuator when writing