2 medium type – IAI America NS User Manual
Page 39

25
6SHFL¿FDWLRQV
6.2
Medium type
Model
Unit
MXMS, horizontal specification
MXMM, horizontal specification
Lead
0
3
0
2
0
3
0
2
Stroke
mm
500 to 1500
500 to 1500
330 to 1530
330 to 1530
Rated thrust
N
170.9
113.9
170.9
113.9
Maximum speed
mm/sec
1200
1800
1200
1800
Rated acceleration
*3
G
0.3
0.3
0.3
0.3
G
0.8
1.0
0.8
1.0
Maximum
acceleration/deceleration
*3
Loading capacity at rated
acceleration
*2
kgf
40
2.5
2.5
0.5
0.5
(When used
horizontally)
(When used
horizontally)
(When used
horizontally)
(When used
horizontally)
(When used
horizontally)
25
(When used
horizontally)
40
(When used
horizontally)
25
(When used
horizontally)
Loading capacity at
maximum acceleration
*2
kgf
Positioning repeatability
mm
r0.01
r0.01
r0.01
r0.01
Ma: 69.6 (7.1)
Ma: 69.6 (7.1)
Ma: 69.6 (7.1)
Ma: 69.6 (7.1)
Mb: 99.0 (10.1)
Mb: 99.0 (10.1)
Mb: 99.0 (10.1)
Mb: 99.0 (10.1)
Load moment
*1
N. m
(kgf cm)
Mc: 161.7 (16.5)
Mc: 161.7 (16.5)
Mc: 161.7 (16.5)
Mc: 161.7 (16.5)
Ma direction:
600 max.
Ma direction:
600 max.
Ma direction:
600 max.
Ma direction:
600 max.
Overhang load length
mm
Mb/Mc directions:
600 max.
Mb/Mc directions:
600 max.
Mb/Mc directions:
600 max.
Mb/Mc directions:
600 max.
*1
Based on an acceleration of 0.3 G and the maximum speed.
*2
The maximum speed is assumed.
*3
The table below shows the relationship of acceleration/deceleration and loading capacity.
These values are not guaranteed and should be used only as a guide.
Even when the acceleration is equal to or below the rated acceleration, the loading capacity remains the same
as the value at the rated acceleration.
Loading capacity by acceleration (kg)
Type
Lead
Maximum speed
0.3G
0.4G
0.5G
0.6G
0.7G
0.8G
0.9G
1.0G
MXMS
20 mm
1200 mm/sec
40
28
18
10
5
2.5
MXMM
30 mm
1800 mm/sec
25
16
10
6
3.5
2
1
0.5
Caution:
x Use each actuator by observing its maximum speed.
x Take note that resonance may still occur at speeds below the applicable limit specified
above, depending on the installation condition or operating conditions.
x Resonance of the ball screw shaft may increase the noise level or cause vibration,
resulting in a shorter service life of the machine.
x If each actuator is used independently, write a program conforming to the maximum
speed of the actuator (refer to the table above). If multiple actuators are used in a
synchronized operation, write a program conforming to the lowest of the maximum
speeds applicable to all synchronized actuators.
x In either way, always check the maximum speed of each applicable actuator when writing
a program.