6SHFL¿FDWLRQV
6.3
Large type
Model
Unit
LXMS, horizontal specification
LXMM, horizontal specification
Lead
0
4
0
2
0
4
0
2
Stroke
mm
500 to 2200
500 to 2200
250 to 2250
250 to 2250
Rated thrust
N
340.1
170.0
340.1
170.0
Maximum speed
mm/sec
1300
2400
1300
2400
Rated acceleration
*3
G
0.3
0.3
0.3
0.3
Maximum
acceleration/deceleration
*3
G
1.0
1.0
1.0
1.0
Loading capacity at rated
acceleration
*2
kgf
80
(When used
horizontally)
40
(When used
horizontally)
80
(When used
horizontally)
40
(When used
horizontally)
Loading capacity at
maximum acceleration
*2
kgf
24
(When used
horizontally)
10
(When used
horizontally)
24
(When used
horizontally)
10
(When used
horizontally)
Positioning repeatability
mm
r0.01
r0.01
r0.01
r0.01
Ma: 104.9 (10.7)
Ma: 104.9 (10.7)
Ma: 104.9 (10.7)
Ma: 104.9 (10.7)
Mb: 149.9 (15.3)
Mb: 149.9 (15.3)
Mb: 149.9 (15.3)
Mb: 149.9 (15.3)
Load moment
*1
N. m
(kgf cm)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Mc: 248.9 (25.4)
Ma direction:
750 max.
Ma direction:
750 max.
Ma direction:
750 max.
Ma direction:
750 max.
Overhang load length
mm
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
Mb/Mc directions:
750 max.
*1
Based on an acceleration of 0.3 G and the maximum speed.
*2
The maximum speed is assumed.
*3
The table below shows the relationship of acceleration/deceleration and loading capacity.
These values are not guaranteed and should be used only as a guide.
Even when the acceleration is equal to or below the rated acceleration, the loading capacity remains the same
as the value at the rated acceleration.
Loading capacity by acceleration (kg)
Type
Lead
Maximum speed
0.3G
0.4G
0.5G
0.6G
0.7G
0.8G
0.9G
1.0G
LXMS
20 mm
1300 mm/sec
80
60
48
40
34
30
27
24
LXMM
40 mm
2400 mm/sec
40
30
25
20
17
15
13
10
Caution:
x Use each actuator by observing its maximum speed.
x Take note that resonance may still occur at speeds below the applicable limit specified
above, depending on the installation condition or operating conditions.
x Resonance of the ball screw shaft may increase the noise level or cause vibration,
resulting in a shorter service life of the machine.
x If each actuator is used independently, write a program conforming to the maximum
speed of the actuator (refer to the table above). If multiple actuators are used in a
synchronized operation, write a program conforming to the lowest of the maximum
speeds applicable to all synchronized actuators.
x In either way, always check the maximum speed of each applicable actuator when writing
a program.