Maintenance inspection, 1 inspection items and schedule, 2 external visual inspection – IAI America RCL-RA3L User Manual
Page 47: 3 cleaning

5. Maintenance Inspection
41
5. Maintenance Inspection
5.1 Inspection Items and Schedule
Follow the maintenance inspection schedule below.
It is assumed that the equipment is operating 8 hours per day.
If the equipment is running continuously night and day or otherwise running at a high operating rate,
inspect more often as needed.
External visual inspection
Start of operation
{
After 1 month of operation
{
After 3 months of operation
{
Every 3 months thereafter
{
After 3 years of operation, or upon reaching 5,000
km in traveled distance
{
Every year thereafter
{
5.2 External Visual Inspection
An external visual inspection should check the following things.
Main unit
Loose actuator mounting bolts, other loose items
Visual inspection on rod sliding area (should be no foreign
object to be put on)
Smooth movement of rod when moving it manually by hand
Cables
Scratches, proper connections
Overall
Irregular noise, vibration
5.3 Cleaning
Ɣ Clean exterior surfaces as necessary.
Ɣ Use a soft cloth to wipe away dirt and buildup.
Ɣ Do not blow too hard with compressed air as it may cause dust to get in through the gaps.
Ɣ Do not use oil–based solvents as they can harm lacquered and painted surfaces.
Ɣ To remove severe buildup, wipe gently with a soft cloth soaked in a neutral detergent or alcohol.