beautypg.com

Φd b a caution label – IAI America RCL-RA3L User Manual

Page 30

background image

2. Installation

24

2.3.2 Installing the Main Body

[1] Mounting Method

Fixation to a mating component with a profile of hole since the body is in a cylindrical profile.

φd

B

A

Caution label

Dimensions for Body Attachment

Type

O.D. of Pipe

I

d (tolerance)

Pipe fixable range

A

Available range for

screw fixing type B

RA1L

16 (0/-0.1)

90

30

RA2L

20 (0/-0.1)

115

40

RA3L

25 (0/-0.1)

164

55

Recommended Fixing Method

Clamping (split clamp)

Clamp with a profile of hole that suits the pipe.

Do not attempt to clamp with a flat plate, nor a profile of the hole, because it may deform the pipe.

This manual is related to the following products: