9. Installation

R0.3 or less

9.3

Mounting Surface

The platform to install the actuator should possess a structure that ensures enough stiffness,

and should be free from vibration.

RCA2-SA3C, SA4C, SA5C, SA6C, SA3R, SA4R, SA5R, SA6R

Follow the diagram below when installing the device using the reference surface.

Model

Length of A (mm)

Slider type

2 to 4 or less

Reference

surface

Reference

surface

Slider type

The side and bottom faces of the base provide reference surfaces for slider travel. When it is
necessary that the slider moves in a highly precise fashion, ensure that the device is installed at
the direction that is based on the position of these surfaces.

Caution: Because the side and bottom faces of the base provide reference surfaces for slider travel

as shown in the above diagram, conduct installation based on the position of this side
when precision is required.