Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual
Page 54

tem. The v3.0+ Kp-300 has a separate pair of screw terminals for attaching
the 24 vdc supply.
Not surprisingly, the inputs to the Kp-300 are all compatible with the digi-
tal outputs on all of our animation control systems. In most cases the digital
outputs will be coming from a Z-Brick.
The digital output from all Gilderfluke & Co, animation systems is called a
ʻJ6ʼ connector. It defines a forty position insulation displacement (IDS) con-
nector and forty wire ribbon cable. In this case, the Kp-300 needs only
twenty-four of the thirty-two outputs in a J6 cable. That is why the Kp-300
connector is a thirty wire ʻ1/3 J6ʼ, The remaining eight outputs on the J6 ca-
ble can be used for any other purposes:
!
Wire #!Color! Bit #!
Description
! 1! Brown!
!
Ground
! 2!
Red! Bit 7!
Show Start Button #8 LED Input
! 3! Orange!Bit 6!
Show Start Button #7 LED Input
! 4! Yellow! Bit 5!
Show Start Button #6 LED Input
! 5! Green! Bit 4!
Show Start Button #5 LED Input
! 6!
Blue! Bit 3!
Show Start Button #4 LED Input
! 7!
Violet! Bit 2!
Show Start Button #3 LED Input
! 8!
Gray! Bit 1!
Show Start Button #2 LED Input
! 9!
White! Bit 0!
Show Start Button #1 LED Input
!10! Black!
!
+ 24 Vdc Supply
!11! Brown!
!
Ground
!12!
Red! Bit 7!
Show Start Button #8 Enable Input
!13! Orange!Bit 6!
Show Start Button #7 Enable Input
!14! Yellow! Bit 5!
Show Start Button #6 Enable Input
!15! Green! Bit 4!
Show Start Button #5 Enable Input
!16!
Blue! Bit 3!
Show Start Button #4 Enable Input
!17! Violet! Bit 2!
Show Start Button #3 Enable Input
!18!
Gray! Bit 1!
Show Start Button #2 Enable Input
!19! White! Bit 0!
Show Start Button #1 Enable Input
!20! Black!
!
+ 24 Vdc Supply
!21! Brown!
!
Ground
!22!
Red! Bit 7!
!23! Orange!Bit 6!
!24! Yellow! Bit 5!
To Kp-300
!25! Green! Bit 4!
To Kp-300
!26!
Blue! Bit 3!
To Kp-300
!27! Violet! Bit 2!
To Kp-300
!28!
Gray! Bit 1!
To Kp-300
!29! White! Bit 0!
To Kp-300
!30! Black!
!
+ 24 Vdc Supply
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485