Kp-300 operator controls, E-stop button/keyswitch, Log belts button – Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual
Page 22: E-stop button and, Keyswitch, E-stop button and keyswitch, Remote log belts button(s), E-stop button, Stop button and keyswitch, Remote log belts but

Kp-300 Operator Controls
The Kp-300 has just a small number of operator controls. Most of these have LEDs
that can be lit under program control, or indicate their current status.
A) E-Stop Button/Keyswitch
These two switches are wired in series. Opening either one will cause an
and
on the Kp-300. The beginning of any E-Stop
event stops the HPU (if there is one), disables the
and
triggers the Smart Brick System to play the E-Stop Show through the
to the Smart Brick Brain. Calling up the E-Stop show sets the
ʼ output from the Smart Brick System (this must be
programmed into the motion profile of the E-Stop show). This resets the first
of the two E-Stop latches on the Kp-300. At this point you can start the HPU
and any shows that have been enabled in the motion control profile of the E-
Stop Show.
The E-Stop switch has a red mushroom-style cap. Once pushed, the but-
ton latches in the E-Stopped position. To release the cap, it is rotated clock-
wise. The
has a spare set SPDT set of contacts available for
your use. Users of Moog electric motion bases can use this switch closure
for the hardware E-Stop input they require.
The
is typically used to lock unauthorized users from starting
the HPU or running shows with motion. The Keyswitch can be turned to one
of two positions. The key can be removed in either of these two positions.
The show can be run without motion while the keyswitch is turned off or
the
has been pushed in. If you want to disallow shows to be
run at all if there is an E-Stop condition present, you can use the
or
to disallow running shows if there is an er-
ror condition.
B) Log Belts Button
Seat belts can be logged at any time that the
from the Smart Brick System is active. When this input is active, the safety
inputs can be logged by either pressing the
or activating the
by pressing
attached to
it. If you want to automatically log belts from the motion profile, just set the
for Internal Power and attach the two wires for this
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 22 of 75