Seat belt logging, E-stop buss, Show pause buss – Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual
Page 29

C) Seat Belt Logging
(One jumper for each safety input)
The fifteen Safety Inputs can be set to be ʻLoggedʼ either manually or
automatically.
Not Logging
Input Logged
Once an input which is open (green LED is not on) has been logged, it
will be ignored until it is logged as active again. This feature is typically used
(as its name implies) to log seat belt inputs. A seat which is unoccupied will
be logged so that it canʼt cause an E-Stop or Pause if it changes state during
the show. A yellow LED indicates an input which has been logged.
The jumper for an input should be placed in the Log Belts position if it is
to be logged. The jumper should be placed on the No Logging position if it is
not to be logged.
Seat belts can be logged at any time that the
from the Smart Brick System 1/3 J6 is active. When this input is active, the
safety inputs can be logged by either pressing the
vating the
by pressing
attached to it.
If you want to automatically log belts from the motion profile, just set the
for Internal Power and attach the two wires for this
input together so it is always active. Whenever the
is programmed active, the inputs that are set to be logged will automatically
be logged.
Input logging actually takes place at the instant that the
, or
next to the
will light whenever the seat belts are being
logged.
D) E-Stop Buss
E) Show Pause Buss
(One jumper for each safety input)
Any or all of the fifteen Safety Inputs can be set to trigger either an E-
Stop or Show Pause.
E-Stop
Show Pause
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 29 of 75