beautypg.com

0 installation, 1 inspection, 2 location – Micromod Micro-DCI: 53ML5100A LOADING STATION User Manual

Page 16: 3 mounting

background image

2.0 INSTALLATION

2.1 INSPECTION

A list of all items in the shipment is attached to the shipping container. Inspect the equipment upon
arrival for damage that may have occurred during shipment. All damage claims should be reported
to the responsible shipping agent before installation is attempted. If damage is such that faulty op-
eration is likely to result, the MicroMod Automation Inc. Customer Service Department should be notified.

Inspect the packing material before discarding it as a precaution to prevent the loss of mounting
hardware or special instructions that may have been included with the shipment. Normal care in
the handling and installation of this equipment will contribute toward its satisfactory performance.

2.2 LOCATION

The 53ML5100 Manual Loading Station is supplied with an enclosure designed specifi-
cally for indoor mounting. The installation site selected should be dry, well lighted, and vibration
free. The ambient temperature should be stable and maintained within the specified minimum and
maximum temperature limits listed in the Specifications, in Section 1.4 of this Instruction Bulletin.

The instrument can be supplied for use with a 24 V dc supply or 120, 220 and 240 V ac line serv-
ice. Instrument power requirements are given on the instrument data tag.

2.3 MOUNTING

2.3.1 GENERAL

It is normally not necessary to open the instrument case during installation. If the instrument must
be removed from the case, refer to Section 5 for details. Incorrect removal procedures may dam-
age the instrument.

The instrument can be flush panel mounted, either as a single unit or side by side in multiple fash-
ion. Appropriate mounting hardware is supplied by MMA. Outline dimensions and panel cut-out re-
quirements for case mounting are shown in Figure 2-1.

The dimensions given for spacing between instruments were selected on the basis of 1/8" thick
panel strength. Panel strength must be considered when multiple case mounting is required. As
the panel cut-out becomes longer it may be necessary to install supporting members because the
panel area between instrument rows becomes weaker to the point where the panel offers very little
support. It is recommended that the 9 inch minimum center line dimension between horizontally
mounted rows be increased as the number of units increases, or that the panel strip be stiffened.

The rear of the instrument case must be supported to prevent panel distortion. Mount an angle
iron or similar member along the bottom of the cases as indicated in Figure 2-2. If the panel is to
be moved the instrument cases must be tied down to prevent damage.

If multiple mounted instruments are installed in a panel that tilts back, it may be necessary to sup-
port the instruments so the panel does not sag. The downward weight should be supported by ad-
ditional panel supports and/or by increasing panel thickness.

Section 2. Installation

2-1