Magnum Venus Plastech Flex Molding Process MKVI Mix User Manual
Page 44

MKVI Mix Meter System Operations Manual
Rev. 08/2013
Page | 44
To access the pump Piston Seal or any other pump internal parts proceed as follows.
1. Pump out catalyst / hardener from system and then remove feed pipe and filter
assembly from catalyst bottle / hardener container. Remove pump guard
2. Remove 4 M8 bolts (0559) from the Lower Block (1855) from pump body. The pump
Cylinder (1857) is now exposed. Remove this by withdrawing down to expose the
pump shaft and piston assembly.
3. Remove the Piston retainer/lower Seal Retainer (1860) to allow removal of back
Bush (1863) and the Piston Seal (3021).
4. Replace with new S
eal. Observe the correct” lip up” orientation of the seal as
detailed on drawing.
5. Reassembled in the reverse order
Pump Piston shaft seal:
The top Seal (3020) can be removed and replaced by following the above description to
remove the pump and disassembly.
1. The Piston assembly (1859) must be removed so that the piston rod can be
withdrawn upwards through the top seal housing (1856) and removed to access
piston rod seal (3020).
2. Remove Circlip (2881) and Retainer washer (1864) and old Seal (3020).
3. Ensure new Seal (3020) is evenly pushed into the top housing with the seal lip
entering first.
4. Reassemble in reverse order.