1.3 Specifications:

Specifications:
Environmental

Indoor Use
Altitude up to 2000m
Operating Temperature: 0

°C to +50°C

(-20

°C to 55°C optional)

Storage Temperature: -40

°C to +85 C

Maximum Relative Humidity : 80% for temperatures

up to 31

°C decreasing linearly to 50% RH at

40

°C

Mains supply voltage fluctuations not to exceed

±10% of the nominal voltage

Transient overvoltage according to INSTALLATION
CATEGORY II (see UL 3101-1 Annex J)
POLLUTION DEGREE 2 in accordance with
IEC 664 (see 3.7.3)
Materials: UL, CSA, VDE approved

Listing:

CE Light Industrial,
UL File #: E192404

Display

Type: 2 lines of 20 characters, VFD
Character Size: 0.3" nominal
User selectable label descriptors and units of
measure

Keypad

Keypad Type: Membrane Keypad
Keypad Rating: Sealed to Nema 4
Number of keys: 16

Enclosure

Size: See Dimensions
Depth behind panel: 6.5" including mating connector
Type: DIN
Materials: Plastic, UL94V-0, Flame retardant
Bezel: Textured per matt finish
Equipment Labels: Model, safety, and user wiring

Power Input

The factory equipped power option is internally
fused. An internal line to line filter capacitor is
provided for added transient suppression.
Order Option AC110: 110VAC: 85 to 127 Vrms,

50/60 Hz

Order Option AC220: 220VAC: 170 to 276 Vrms,

50/60 Hz

Order Option DC12:

12VDC: 10.5 to 14 VDC

Order Option DC24:

24VDC: 18 to 24 VDC

Flow Inputs:

Pulse Inputs:

Number of Flow Inputs: one
Configurations supported: single input or
quadrature (menu selectable)
Input Impedance: 10 K

Ω nominal

Pullup Resistance: 10 K

Ω to 5 VDC (menu

selectable)

Pull Down Resistance: 10 K

Ω to common

Trigger Level: (menu selectable)

High Level Input
Logic On:

3 to 30 VDC

Logic Off:

0 to 1 VDC

Low Level Input (mag pickup)

Selectable sensitivity: 10 mV & 100 mV

Minimum Count Speed: Selectable: 1 - 99 secs
Maximum Count Speed: Selectable: 40, 3k, 20kHz
Overvoltage Protection: 50 VDC
Fast Transient: Protected to 500 VDC

(Capacitive Clamp)

Auxilliary/Compensation Inputs

The compensation inputs are menu selectable for
temperature, pressure, density or not used.

Operation: Ratiometric
Accuracy: 0.01% FS
Thermal Drift: Less than 100 ppm/C
Basic Measurement Resolution: 16 bit
Update Rate: 1 update/sec minimum
Automatic Fault detection:

Signal Over-range/under-range
Current Loop Broken
RTD short
RTD open
Fault mode to user defined default settings
Transient Protection: 500 V (Capacitive Clamp)
Reverse Polarity: No ill effects
Over-Voltage Limit (Voltage Input): 50 VDC

Available Input Ranges

Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
Current: 4-20 mA, 0-20 mA
Resistance: 100 Ohms DIN RTD or

Proprietary Thermistor - YSI55016

100 Ohm DIN RTD (DIN 42-760, BS 1904):

Three Wire Lead Compensation
Internal RTD linearization learns ice point

resistance

1 mA Excitation current with reverse polarity

protection

Temperature Resolution: 0.01 C

Control Inputs

Switch Inputs are menu selectable for Start, Stop,
Reset, Lock, Inhibit, Alarm Acknowledge, Print or
Not Used.
Control Input Specifications

Input Scan Rate: 10 scans per second
Logic 1: 4 - 30 VDC
Logic 0: 0 - 0.8 VDC
Transient Suppression: 500 V fast transient

(Capacitive Clamp)

Input Impedance: 100 K

Control Activation: Positive Edge or Pos. Level
based on product definition

Excitation Voltage

110/220 VAC Powered Units

Menu Selectable: 5, 12 or 24 VDC @ 100mA

24 VDC Powered Units

Menu Selectable: 5 or 12 VDC @ 100mA

12 VDC Powered Units

5 VDC @ 100mA

Fuse
Internal self resetting fuse supplied

Relay Outputs

The relay outputs are menu assignable to
(Individually for each relay) Low Rate Alarm, Hi
Rate Alarm, Prewarn Alarm, Preset Alarm,
Temperature, Pressure, Density, Pulse Output
(pulse options) or General purpose warning
(security).

Number of relays: 2 (4 optional)
Contact Style: Form C contacts
Contact Ratings:

250 VAC @ 5 amps
30 VDC @ 5 amps

Fast Transient Threshold: 1000 V