SP3850 Flow Computer

SETUP RELAYS

Rly1

Rly2 Rly3 Rly4

RELAY 1 USAGE
RATE TOTAL NA

RELAY 1 DELAY sec
0

RELAY 1 MODE
LO_ALARM HI_ALARM

RELAY 1 DURATION

#####

RELAY 1 SETPOINT

####### gal

RELAY 1 HYSTERESIS

##### gal/m

Advance To

SETUP RELAYS 3, 4

Sub-menus

Display

Notes

ENTER

ENTER

ENTER

ENTER

ENTER

6.3.14
SETUP RELAYS
(Relay 1 & Relay 2)

ENTER

Select the desired Relay for setup.
(Relays 3 & 4 Optional)

If Relay 1 or Relay 2 Selected,
Select Rate, Total or NA.

If Rate selected, enter desired relay activation
delay value.

Select the desired Relay Activation.
Low: Relay activates when reading is below

setpoint.

High:Relay activates when reading is above

setpoint.

If Total Selected, Enter desired Relay
Duration.

Enter the desired Setpoint. The Setpoint can
be edited in run mode using the PRE 1 key
(PRE 2 key for Relay 2).

If Rate, selected, Enter desired Relay
Hysteresis.

NOTE:

In Batch mode,
Relay 1 is reserved
for Preset,
Relay 2 is reserved
for Prewarn.

ENTER