SP3850 Flow Computer

30

6.3.10
SETUP AUX 2 INPUT

NOTE:
When Density (Dens)
is selected, The menu
prompts will be very
similar to thePressure
prompts.
The menus will
prompt the user for
density values and
density units.

SETUP AUX2 INPUT

AUX 2 INPUT TYPE
None Dens

Press

AUX 2 SIGNAL TYPE
Voltage Current

CURRENT RANGE
4-20mA 0-20mA

AUX LOW SCALE
###### PSIA

AUX FULL SCALE
###### PSIA

AUX LOW ALARM
###### PSIA

AUX HIGH ALARM
###### PSIA

DENS EXTRACT METHOD
Therm_Coef API_2540

Advance To

SET FLUID PROPERTIES

ENTER

ENTER

ENTER

ENTER

Press ENTER to begin setup of the Auxiliary
Input 2.

Select Pressure to set the Auxiliary Input 2 for
Pressure inputs.

Choose Pressure Signal Type.

If Current selected,
Choose desired Current Range.

Enter the low pressure scale corresponding to
the low pressure signal.

Enter the high pressure scale corresponding
to the high pressure signal.

Enter the Low setpoint for the Pressure Alarm.

Enter the High setpoint for the Pressure
Alarm.

If None or Press selected, Choose the Density
Extraction method to be used.*

ENTER

ENTER

ENTER

ENTER

Sub-menus

Display

Notes

ENTER

* If not Density transmitter and not RTD.