beautypg.com

Safety instructions, Warning, Symbols used on unit – Liquid Controls SP3850 User Manual

Page 2: Technical improvements

background image

SAFETY INSTRUCTIONS

The following instructions must be observed.

• This instrument was designed and is checked in accordance with regulations in force EN 60950 (“Safety of

information technology equipment, including electrical business equipment”).
A hazardous situation may occur if this instrument is not used for its intended purpose or is used incorrectly.
Please note operating instructions provided in this manual.

• The instrument must be installed, operated and maintained by personnel who have been properly trained.

Personnel must read and understand this manual prior to installation and operation of the instrument.

• This instrument is internally fused. Replace the internal fuse with the following specified type and rating only:

Input Power

Recommended Fuse

115 VAC

160 mA slow blow fuse

230 VAC

80 mA slow blow fuse

12-24 VDC

800 mA slow blow fuse

Disconnect power supply before replacing fuse!

• The manufacturer assumes no liability for damage caused by incorrect use of the instrument or for modifications

or changes made to the instrument.

Symbols Used On Unit

Number

Symbol

Publication

Description

1

IEC 417, No. 5031

Direct current

2

IEC 417, No. 5172

Equipment protected throughout by DOUBLE
INSULATION or REINFORCED INSULATION
(equivalent to Class II of IEC 536–see annex H)

3

!

ISO 3864, No. B.3.1

Caution (refer to accompanying documents)

Technical Improvements

• The manufacturer reserves the right to modify technical data without prior notice.

Proprietary Notice

The information contained in this publication is derived in part from proprietary and patent data. This information has been
prepared for the expressed purpose of assisting operating and maintenance personnel in the efficient use of the instrument
described herein. Publication of this information does not convey any rights to use or reproduce it or to use for any purpose
other than in connection with the installation, operation and maintenance of the equipment described herein.

Copyright 1999

Printed in USA. All Rights Reserved.

WARNING!

This instrument contains electronic components that are susceptible to damage by static electricity. Proper handling*
procedures must be observed during the removal, installation, or handling of internal circuit boards or devices.

*Handling Procedure

1. Power to unit must be removed.

2. Personnel must be grounded, via wrist strap or other safe, suitable means, before any printed circuit board or other
internal device is installed, removed or adjusted.

3. Printed circuit boards must be transported in a conductive bag or other conductive container. Boards must not be
removed from protective enclosure until the immediate time of installation. Removed boards must be placed immediately
in protective container for transport, storage, or return to factory.

Comments

This instrument is not unique in its content of ESD (electrostatic discharge) sensitive components. Most modern electronic
designs contain components that utilize metal oxide technology (NMOS, CMOS, etc.). Experience has proven that even
small amounts of static electricity can damage or destroy these devices. Damaged components, even though they appear
to function properly, may exhibit early failure.

!

!