beautypg.com

1 – baud rate, 2 – eol character, 5 – print timeout – Liquid Controls Sponsler T675 - Cryogenic System Register User Manual

Page 34

background image

Sponsler, Inc.

Model T675 Flow Totalizer

Technical Information

Pg. 31

3.3.2.4.1 – Baud rate
Establishes the communications rate to the printer.

Example: Program the baud rate at 9600; <4>

*************** Baud rate **************

Current setting = 4


1 – 1200
2 – 2400
3 – 4800
4 - 9600

Enter setting (ESC to exit)?

3.3.2.4.2 – EOL character
Selects the End of Line character.

Example: Program the EOL for CR+LF; <4>

************* EOL character ************

Current setting = 4


1 – none
2 – CR
3 – LF
4 – CR+LF

Enter setting (ESC to exit)?


3.3.2.4.3 – Use Bluetooth
Actives or deactivates Bluetooth communications.

Example: Activate Bluetooth; <1>

************* Use Bluetooth ************

Current setting = 0



Enter setting (ESC to exit)?

3.3.2.5 – Print timeout
Establishes the period of time in seconds delivery data is available for outputting to the printer after delivery activity
has terminated.

Example: Set the printer timeout for 5 minutes; <300>

**** Print timeout secs (0=disabled) ***

Current setting = 300



Enter setting (ESC to exit)?