beautypg.com

Programming, 1 – set clock – Liquid Controls Sponsler T675 - Cryogenic System Register User Manual

Page 10

background image

Sponsler, Inc.

Model T675 Flow Totalizer

Technical Information

Pg. 7

3. PROGRAMMING:

The T675 Initialization Options Menu is accessed when the unit is off by depressing and holding the RESET key while
momentarily depressing and releasing the On/Off pushbutton. Options 1,2, and 3 in this menu contain the entire program
configuration Displays to customize the T675. Simply select the corresponding number. If the Programming Enable
Module is attached Option 2 - Adjustment Mode will display Disabled.

Example: Access Change system settings <3>

****** 675 Initialization options ******

1 - Set clock

#%

2 – Adjustment Mode

#

3 - Change system settings

%

4 – Update software

*%

5 - Hardware test/calibrate

6 - Restart system

7 – Serial Echo/Debug

*

8 – Loaner
9 – LCD setup

Option?

# Passcode required (items 2 & 3)
% T675-PEM must not be installed (items 2,4 & 5)
* Privileged passcode is required (items 5 & 8)

NOTE: 1) Items 2,4 & 5 show “disabled” if the PEM is installed

2) Entry of the Passcode is not displayed, a * is displayed with each digit maintaining confidentiality.
3) Depressing the RESET key during data entry will return the display to the previous menu Display
without changing the data.
4) Any item within the < > borders signifies depressing that key or pushbutton.
5)

 key backspaces an entry 1 position each time it is depressed

6) CLEAR key deletes entire entry

3.1 – SET CLOCK:

Sets the T675's real time clock and Daylight Saving Time (DST) start and end dates. Depressing the RESET softkey
anytime during the entry sequence aborts programming and returns to the Setting clock display. Depressing the RESET
softkey a second time returns to the 675 Initialization Options display.

****** Setting clock ******

1 – Set time
2 – DST start
3 – DST end

Option?