5 – pump on during alarm, 6 – count while temp fail, 3 – serial numbers – Liquid Controls Sponsler T675 - Cryogenic System Register User Manual
Page 22: 1 – flowmeter

Sponsler, Inc.
Model T675 Flow Totalizer
Technical Information
Pg. 19
3.3.1.2.5 – Pump on during alarm
Selects whether the pump is disabled <0> or enabled <1> during a temperature alarm
Example: Disable the pump during a temperature alarm; <0>
** Pump on during alarm (0-NO, 1=YES) **
Current setting = 0
Enter setting (ESC to exit)?
Note:
3.3.1.2.6 – Count while temp fail
When the temperature alarm discontinues, the Pump Cooldown Timer will be
activated keeping the pump disabled until the programmed time has elapsed.
Permits totalization at the default temperature in the event of a catastrophic failure of the temperature
probe (RTD) or probe cable (resistance <100 or >2000
Ω).
Example: Enable totalizer to count during temp failure; <1>
** Count while temp fail(0-NO, 1=YES) **
Current setting = 1
Enter setting (ESC to exit)?
3.3.1.3 – Serial numbers
Permits recording serial numbers for the following menu items. Options 4 & 5 are displayed as “N/A” at
the User access level. Depress the corresponding number in left column to access that menu item.
************ Serial numbers ************
1 – Flowmeter
2 – Plant
3 - Trailer
*
4 – 675 S/N
*
5 – Manufacture date DDMMYY
6 – BT authenticate #
Enter setting (ESC to exit)?
* Privileged passcode is required (items 4 & 5).
3.3.1.3.1 – Flowmeter
Enters the assigned serial number into memory.
Example: S/N12345; <12345>
*************** Flowmeter **************
Current setting = 01234
Enter setting (ESC to exit)?