The Diagnostics screen is for viewing only. None of the
fields are editable.

Diagnostics

Pulser Faults represents the number of false or missing
pulses detected during the last delivery.

Supply Voltage represents the current voltage being
supplied to the system. If the supply voltage is greater
than 17.7 volts, this reading will be inaccurate.

Flow Rate (Units/Rate Base) indicates the current flow
rate through the metering device.

Software indicates the software being used by the Lec-
troCount register.

Language indicates the software language being used
by the LectroCount register.

Ticket indicates the ticket software being used by the
LectroCount register.

Machine Status

Switch is an indication of the position of the red selector
switch on the LectroCount. Changing the switch posi-
tion will change the display to one of the following: RUN,
STOP, PRINT, SHIFT PRINT,
or CALIBRATION.

LCR State is the current state of the system. It will dis-
play one of the following: Calibrate, End Delivery, etc...

Printing will display either YES or NO depending on
whether or not there are any printer errors.

Other Errors indicates whether there are other errors
detected by the system.

Printer Status

Delivery Ticket? indicates that a Delivery Ticket has
been requested.

Shift Ticket? indicates that a Shift Ticket has been re-
quested.

Diagnostic Ticket? indicates that a Diagnostic Ticket
has been requested.

Pass-Through Print? indicates that a line of text that
will print has been given to the LectroCount from the host
computer .

Printer Error? indicates if there is an error detected with
the printer.

Printer Busy? indicates that the print processor has be-
gun to print a ticket.

Delivery Status

ROM Check? indicates if a delivery could not be started

due to the checksum of the LectroCount program code

space failing.

Temperature? indicates if the currently delivery was not

started or was terminated due to an error detected with

the temperature reading hardware.

Watchdog? indicates if the processor was reset due to

a LectroCount watchdog timeout error.

VCF Setup? indicates if there was an error setting up

the volume compensation factor for the current product.

VCF Domain? indicates if the temperature of the prod-

uct being delivered is outside the valid range for the com-

pensation type of the product.

Meter Calibration? indicates if an error occurred while

setting up the meter calibration for the current delivery.

Pulser Failure? indicates if the current delivery was ter-

minated due to too many pulser faults.

Preset Stop? indicates if a gross or net preset volume

has been reached.

No-Flow Stop? indicates if the current delivery was
stopped due to no flow being detected through the meter
for a specified amount of time.

Stop/Pause Request? indicates if the STOP command
was issued during an active delivery.

Print/End Request? indicates if the PRINT command
was issued during an active delivery.

Power Failure? indicates a delivery ended due to a
power fail condition for more than 15 seconds.

Preset Error? indicates if a deliver ended due to an er-
ror condition while attempting to set up a gross or net
preset.

RS-232 Lappad? indicates if the RS-232 Lappad has
been disconnected from the LectroCount during an ac-
tive delivery.

Printer? indicates if the current delivery requires a ticket
to be printed and the printer is either off-line or busy.