Configure LCR - System Calibration
The System Calibration section of General Setup is used
to set parameters associated with system. These fields
will not be active unless the LectroCount selector switch
is in the calibration position. Some fields are not editable
even when the switch is in the calibration position.
Meter ID
This field allows the user to uniquely identify a Lectro-
Count/Meter combination in systems where the Lectro-
Count is part of a multiple meter system. It is important
that this is a unique number. It is recommended that the
meter serial number be entered. This number will print
on all calibration and diagnostic tickets for future refer-
ence.
Click on the green lock indicator to open a Field Edit
Window. Enter up to 10 alpha-numeric characters click
on Write to LCR to accept the value. This field may be
left blank.
Ticket Required?
This field allows the user to decide whether a delivery
ticket will be required for each delivery. Most Weights &
Measures governed truck applications will require a ticket.
Click on the green lock indicator to open a List Box Win-
dow. If “NO” is selected, the system will not require a
ticket to be printed after each delivery. If “YES” is se-
lected, the LectroCount will not allow deliveries to be
made unless a ticket is in the printer and the printer is
operational. It will also require a ticket be printed before
another delivery can be started. Click on Write to LCR
once a selection has been made.
NOTE: Selecting NO will still allow a ticket to be printed
if the printer is connected, loaded with paper, and ready
to print.