Configure LCR - General Setup

The Configure LCR Menu is broken down into five
submenus. These are General Setup, System Calibra-
tion, Product Calibration, Diagnostics, and Security.
These will be covered in the order that they appear.

General Setup

This menu contains fields for general operating param-
eters.

Unit ID

This field represents an ID code that can be used to
uniquely identify the driver, location, or truck to which
the LectroCount is associated.

Click on the green lock indicator to open a Field Edit
Window. Enter an alpha-numeric code up to 10 charac-
ters in length. Click on Write to LCR.

Date Format

This field defines the date format. Click on the green
lock indicator to open a List Box Window which contains
the options: MM/DD/YY and DD/MM/YY. Select the de-
sired option and click on Write to LCR.

MM/DD/YY = Month/Day/Year
DD/MM/YY = Day/Month/Year

Date

This field indicates the current date. Click on the green
lock indicator to open a Field Edit Window. Use the up
and down arrows for hour, minutes, and seconds to set
the current time of day. Click on Write to LCR when the
time has been set.

Presets Allowed

This field indicates which type of preset will be allowed.
Click on the green lock indicator to open a List Box Win-
dow with the options: NONE, GROSS, NET, and BOTH.

NONE = No presets are allowed.
GROSS = Gross presets are allowed.
NET = Net presets are allowed.
BOTH = Gross and net presets are allowed.

Select the desired option and click on Write to LCR.

NOTE: If the preset feature is to be used, ensure that
the “S1 CLOSE” field (Page 47) is set for a preset value
to work properly.