beautypg.com

Configure lcr - product calibration – Liquid Controls WinHost Operation User Manual

Page 26

background image

26

Product Calibration fields are used to adjust individual
calibration factors for each of the product codes for the
LectroCount.

Product

The product number will correspond to one of the prod-
uct types/calibrations that can be set up in the Lectro-
Count. At least one product must be calibrated to allow
for deliveries.

Click on the green lock indicator to open a List Box Win-
dow with the four product options. Select the desired
product number and click on Write to LCR.

Code

This field corresponds to Product. Code can also be
entered in the Preset And Delivery menu. Click on the
green lock indicator to open a Field Edit Window. Type
in the desired Code and click on Write to LCR.

Name

This field contains a description of the product that will
appear on the delivery ticket. Click on the green lock
indicator to open a Field Edit Window and enter up to 18
alpha-numeric characters. Click on Write to LCR.

Configure LCR - Product Calibration

Type

This field is used to specify the type of product that will
be delivered with the current Product Calibration being
set up. Click on the green lock indicator to open a List
Box Window with the options: AMMONIA, AVIATION,
DISTILLATE, GASOLINE, METHANOL, LPG, LUBE OIL,
and NO PRODUCT.

Select the desired option and click on Write to LCR.

Compensation Type

If a temperature probe is being used for the application,
the type of temperature volume compensation must be
selected for the Product. It is necessary to make a se-
lection for proper Net (temperature compensated) cal-
culations.

There are ten options for Compensation Type. Click on
the green lock indicator to open a List Box Window and
select the desired type.

NOTE: If “NONE” is selected, deliveries can only be made
in gross (non-compensated) quantities.

Refer to the Compensation Types & Parameters table
(Page 27) to assist in making the correct selection.