beautypg.com

Troubleshooting – Controlled Products Systems Group HRG 220-A ST User Manual

Page 67

background image

Installation and Maintenance Manual

53

Troubleshooting


The Smart Touch Controller system includes many self diagnostic capabilities. The LCD will display specific
messages and the Audio Alert buzzer will sound distinctive chirps. Any Alerts, Faults or Errors are also logged into
a memory and stamped with a time and date. For diagnostic purposes, these messages can be retrieved with
optional WinLogger software available from HySecurity Gate.

The following chart is a listing of codes that would appear on the LCD display if problems are

detected by the Smart Touch Controller.

Error, Fault, or Alert Status

LCD Display

Buzzer Chirp Sequence

Cannot respond due to tripped
sensor or in Entrapment mode

Entr

2 chirps/sec every 2 seconds while control input
is active

Safety Mode Alert

SAFE

2 chirps once when in Safety Mode

Low 24V Control Voltage Alert

Lo24 (ac or dc)

N/A (LCD flashes once every 5 seconds)

Critical Low 24V supply power

BadP (ac or dc)

N/A Display steady

– controls disabled

Dead 24V Battery Alert

–DC only

bat - dEAd

3 chirps upon any operating command

Gate forced open Alert

ALE1

2 pulses/sec for 30 seconds

Gate drift closed Alert

ALE2

2 pulses/sec for 10 seconds

Motor thermal overload Alert

ALE4

2 chirps/sec every 15 seconds

Both limits tripped Alert

ALE5

2 chirps/sec every 15 seconds

Limits not released in 10 seconds

ALE6

2 chirps/sec every 15 seconds

Loop abnormal freq change alert

ALE7

2 chirps/sec every 15 seconds

Loop shorted to ground alert

ALE8

2 chirps/sec every 15 seconds

Loop disconnected alert

ALE9

2 chirps/sec every 15 seconds

Loop detector comm. alert

AL10

2 chirps/sec every 15 seconds

Loop detector function alert

AL11

2 chirps/sec every 15 seconds

Loop detector active >5 minutes

AL12

2 chirps/sec every 15 seconds

General I2C Comm. Buss failure

AL16

2 chirps/sec every 15 seconds

Bad 3V coin battery

AL17

2 chirps/sec every 15 seconds

Lock Intrlk (Input #22) Blocks Open

AL20

2 chirps/sec every 15 seconds

Maximum run Fault

FAL1

1 chirp once every 15 seconds

Photo eye Fault (supervised)

FAL2

2 chirps/sec once per minute

Critical AC sag

– bad supply wire

FAL3

2 chirps/sec once per minute

Directional motion Error

Err1

3 chirps/sec once per minute

Disconnected IES Error

Err2

3 chirps/sec once per minute

Loop detector failed

Err3

3 chirps/sec once per minute

Master/slave RS485 comm. Error

Err4

3 chirps/sec once per minute

EEPROM Data Error (factory)

Err7

3 chirps/sec once per minute

EEPROM Data Error (installer)

Err8

3 chirps/sec once per minute

EEPROM Data Error (user menu)

Err9

3 chirps/sec once per minute

Program Data Error

FAiL

3 chirps/sec once per minute

This manual is related to the following products: